Arcoaire / AIR-SOURCE HEAT PUMP

H5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 10

415 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for H5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18415 / 415
EER2 · BTU/Wh11.7–13.5415 / 415
HSPF2 · BTU/Wh7.8–8.5415 / 415
Cooling capacity · BTU/h45,500–50,500415 / 415
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500415 / 415
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400415 / 415
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600415 / 415
COP at 5°F / −15°C2.1–2.34415 / 415
Equipment / loop typeHP - Split System415 / 415
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)415 / 415
Compressor stagingTwo-stage415 / 415
Connected capabilityNo415 / 415

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X49M24A*+ furnace: *80VTL1102122B*AHRI reference: 21635059216.508.10248002.14EPA 3803881 →
EVD5X49M24A*+ furnace: *96VSN1002120B*AHRI reference: 21635062416.508.10252002.14EPA 3803887 →
EVD5X49M24A*+ furnace: *96VSN1202422B*AHRI reference: 21635063216.508.10252002.12EPA 3803895 →
EVD5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21635138516.508.10252002.14EPA 3803934 →
EA*5X61M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635240116.508.00254002.22EPA 3804039 →
EA*5X61M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635240916.508.00250002.22EPA 3804048 →
EA*5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635242516.508.10256002.24EPA 3804064 →
EA*5X61M24A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 21635292116.508.00250002.24EPA 3804148 →
EVM5X49M21A*+ furnace: *96VTN0802120B*AHRI reference: 21634990416.508.10250002.14EPA 3804179 →
EVM5X49M21A*+ furnace: *96VTN1002120B*AHRI reference: 21634991216.508.10250002.12EPA 3804186 →
EVD5X49M24A*+ furnace: *96VSN0802120B*AHRI reference: 21635061616.508.10254002.12EPA 3805212 →
EVD5X49M24A*+ furnace: *96VTN0802120B*AHRI reference: 21635067216.508.10254002.12EPA 3805219 →
EVD5X49M24A*+ furnace: *96VTN1002120B*AHRI reference: 21635068016.508.10254002.12EPA 3805227 →
EVM5X49M21A*+ furnace: *97VTN0802120A*AHRI reference: 21634996016.508.00250002.12EPA 3805379 →
EVM5X49M21A*+ furnace: *97VTN1002120A*AHRI reference: 21634996816.508.00250002.10EPA 3805387 →
EVD5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 21635145716.508.10252002.14EPA 3805693 →
EVD5X61M24A*+ furnace: *97VTN1202422A*AHRI reference: 21635152916.508.00252002.12EPA 3805893 →
EVM5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21635016816.508.10248002.14EPA 3805937 →
EVM5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 21635017616.508.10246002.16EPA 3805945 →
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 21635252116.508.10256002.24EPA 3806042 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →