Arcoaire / AIR-SOURCE HEAT PUMP

H5H8T36*K*AAA*

Mainline 18 SEER2 HP · source records, page 3

188 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for H5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 188 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5188 / 188
EER2 · BTU/Wh11.7–13188 / 188
HSPF2 · BTU/Wh7.8–8.5188 / 188
Cooling capacity · BTU/h33,800–38,000188 / 188
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000188 / 188
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200188 / 188
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600188 / 188
COP at 5°F / −15°C1.84–2.4188 / 188
Equipment / loop typeHP - Split System188 / 188
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)188 / 188
Compressor stagingTwo-stage188 / 188
Connected capabilityNo188 / 188

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635731315.508.00193002.24EPA 3807883
EA*5X37M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635732115.508.00193002.24EPA 3807891
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635733715.508.10193002.28EPA 3807907
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635734515.508.10195002.28EPA 3807914
EA*5X37M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21635736915.508.00193002.24EPA 3807923
EA*5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635875315.508.00191002.26EPA 3807934
EA*5X42M21A*+ furnace: *96VTN1002122B*AHRI reference: 21635802515.508.10188002.28EPA 3807939
EA*5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635888115.508.10193002.26EPA 3807980
EA*5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635876115.508.00191002.26EPA 3807993
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635877715.508.10192002.28EPA 3808009
EA*5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635878515.508.10191002.28EPA 3808017
ESH5X42M12A*+ furnace: *80MSU0802120A*AHRI reference: 21635965715.508.10190002.28EPA 3808031
EA*5X37M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635740915.508.00194002.24EPA 3808065
EA*5X37M21A*+ furnace: *96VSN0802120B*AHRI reference: 21635743315.508.10193002.28EPA 3808073
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635744115.508.10194002.28EPA 3808081
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 21635745715.508.10193002.28EPA 3808097
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21635746515.508.10194002.28EPA 3808105
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 21635747315.508.10194002.30EPA 3808113
EA*5X37M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21635750515.508.00194002.24EPA 3808121
EA*5X43M21A*+ furnace: *80VSL0701716B*AHRI reference: 21635816915.508.10194002.26EPA 3808129

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →