H5H6S36*K*AAA*
MAINLINE 16 SEER2 HP
30 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H6S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 30 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–15.5 | 30 / 30 |
| EER2 · BTU/Wh | 11.7–13 | 30 / 30 |
| HSPF2 · BTU/Wh | 7.8 | 30 / 30 |
| Cooling capacity · BTU/h | 33,800–36,800 | 30 / 30 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,200 | 30 / 30 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 30 / 30 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,700–18,100 | 30 / 30 |
| COP at 5°F / −15°C | 2–2.24 | 30 / 30 |
| Equipment / loop type | HP - Split System | 30 / 30 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 30 / 30 |
| Compressor staging | Single stage | 30 / 30 |
| Connected capability | No | 30 / 30 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FHMA5*48L*C*AHRI reference: 214165319 | 15.50 | 7.80 | 17500 | 2.24 | EPA 3404300 → |
FTMA5B48L0C*AHRI reference: 214165263 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404412 → |
FEVB0048**+NAVA54801CKAHRI reference: 214277699 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3415828 → |
FMA5X36**AL*AHRI reference: 214424325 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425203 → |
F5MA5*48L*C*AHRI reference: 216464040 | 15.50 | 7.80 | 17500 | 2.24 | EPA 3846952 → |
FEVA0048**+NAVA54801CKAHRI reference: 217051673 | 15.50 | 7.80 | 17400 | 2.22 | EPA 4001134 → |
EVD5X42M24A*+ furnace: *80MSU1002120A*AHRI reference: 214155653 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401963 → |
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 214154322 | 15.20 | 7.80 | 17000 | 2.18 | EPA 3402083 → |
EA*5X43M21A*+ furnace: *80CSU1002120A*AHRI reference: 214154330 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3402091 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 214154837 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3402100 → |
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 214154845 | 15.20 | 7.80 | 17300 | 2.20 | EPA 3402108 → |
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 214153850 | 15.20 | 7.80 | 17100 | 2.16 | EPA 3402199 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214154757 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3402343 → |
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214154765 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3402351 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 214154789 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3402359 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214154370 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3402545 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214154378 | 15.20 | 7.80 | 18000 | 2.20 | EPA 3402549 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 214154893 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3402562 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 214154917 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3402570 → |
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 214155005 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3402586 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →