Arcoaire / AIR-SOURCE HEAT PUMP

H5H6S24*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 4

193 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for H5H6S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 193 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5193 / 193
EER2 · BTU/Wh11.7–13193 / 193
HSPF2 · BTU/Wh7.8–8.5193 / 193
Cooling capacity · BTU/h22,200–24,400193 / 193
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000193 / 193
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200193 / 193
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900193 / 193
COP at 5°F / −15°C1.98–2.26193 / 193
Equipment / loop typeHP - Split System193 / 193
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)193 / 193
Compressor stagingSingle stage193 / 193
Connected capabilityNo193 / 193

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 21415740315.507.80114002.10EPA 3402437
EVD5X31M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 21416160715.507.80113001.98EPA 3402460
EA*5X37M17A*+ furnace: *92MSN0601714A*AHRI reference: 21415821115.507.80113002.08EPA 3402481
EA*5X37M17A*+ furnace: *92MSN0801716A*AHRI reference: 21415821915.507.80113002.10EPA 3402488
EA*5X37M17A*+ furnace: *96MSN0801716A*AHRI reference: 21415824315.507.80113002.08EPA 3402511
EVM5X31M17A*+ furnace: *95MSU0601716A*AHRI reference: 21415917115.507.80113001.98EPA 3402592
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 21415745915.507.80115002.10EPA 3402615
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 21415746715.507.80115002.12EPA 3402623
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21415743515.507.80113002.10EPA 3402629
EA*5X37M17A*+ furnace: *96CTN0601714B*AHRI reference: 21415832315.507.80114002.08EPA 3402642
EA*5X37M17A*+ furnace: *96CTN0801714B*AHRI reference: 21415833115.507.80113002.08EPA 3402650
EA*5X37M17A*+ furnace: *95MSU0601716A*AHRI reference: 21415829915.507.80113002.08EPA 3402658
EA*5X25M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 21416086315.507.80112002.12EPA 3402692
EA*5X25M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21416087115.507.80114002.12EPA 3402699
EVD5X38M17A*+ furnace: *80MS(N,L)0451714A*AHRI reference: 21416002315.507.80115001.98EPA 3402708
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21415837915.507.80113002.12EPA 3402796
EA*5X37M21A*+ furnace: *80CSU1002120A*AHRI reference: 21415838715.507.80115002.12EPA 3402972
EVD5X38M17A*+ furnace: *96VSN0601716B*AHRI reference: 21416011115.507.80114001.98EPA 3403084
EVD5X38M17A*+ furnace: *96VSN0801716B*AHRI reference: 21416011915.507.80113001.98EPA 3403092
EVD5X38M17A*+ furnace: *96VTN0601716B*AHRI reference: 21416015115.507.80114001.98EPA 3403100

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →