Arcoaire / AIR-SOURCE HEAT PUMP

H5H6S18*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 2

46 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,400–18,900BTU/h

Each efficiency range summarizes published EPA records for H5H6S18*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 46 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.546 / 46
EER2 · BTU/Wh11.7–12.546 / 46
HSPF2 · BTU/Wh7.8–846 / 46
Cooling capacity · BTU/h17,400–18,90046 / 46
Heating capacity at 47°F / 8.3°C · BTU/h16,400–18,10046 / 46
Heating capacity at 17°F / −8.3°C · BTU/h10,500–10,90046 / 46
Heating capacity at 5°F / −15°C · BTU/h8,200–8,50046 / 46
COP at 5°F / −15°C1.94–2.146 / 46
Equipment / loop typeHP - Split System46 / 46
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)46 / 46
Compressor stagingSingle stage46 / 46
Connected capabilityNo46 / 46

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X19M17A*+ furnace: *80MSU0601716A*AHRI reference: 21415039215.207.8084002.04EPA 3401622
EA*5X19M17A*+ furnace: *80CTL0701412B*AHRI reference: 21415041615.207.8084002.04EPA 3401628
EA*5X19M17A*+ furnace: *80MS(N,L)0451412A*AHRI reference: 21415029615.207.8084002.02EPA 3401636
EA*5X19M17A*+ furnace: *80MS(N,L)0701412A*AHRI reference: 21415030415.207.8084002.04EPA 3401644
EA*5X19M17A*+ furnace: *80VSL0701716B*AHRI reference: 21415036015.207.8084002.04EPA 3401664
EA*5X19M17A*+ furnace: *80ESU0401712A*AHRI reference: 21415036815.207.8083002.04EPA 3401672
EA*5X19M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 21415031215.207.8083002.04EPA 3401687
EA*5X19M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21415032015.207.8084002.04EPA 3401696
EA*5X19M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21415032815.207.8084002.04EPA 3401803
EA*5X19M17A*+ furnace: *80VSL0451412B*AHRI reference: 21415034415.207.8084002.04EPA 3401810
EA*5X19M17A*+ furnace: *80CTL0901716B*AHRI reference: 21415043215.207.8084002.02EPA 3401820
EA*5X19M17A*+ furnace: *92MSN0601714A*AHRI reference: 21415050515.207.8084002.04EPA 3401844
EA*5X19M17A*+ furnace: *92MSN0801716A*AHRI reference: 21415051315.207.8084002.04EPA 3401852
EA*5X19M17A*+ furnace: *95MSU0601716A*AHRI reference: 21415056915.207.8084002.04EPA 3401875
EA*5X19M17A*+ furnace: *96CTN0801714B*AHRI reference: 21415058515.207.8084002.02EPA 3401883
EA*5X25M17A*+ furnace: *80MS(N,L)0451412A*AHRI reference: 21415065715.207.8084002.04EPA 3401899
EA*5X25M17A*+ furnace: *80MS(N,L)0701412A*AHRI reference: 21415067315.207.8084002.06EPA 3401907
EA*5X25M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 21415068115.207.8084002.06EPA 3401915
EA*5X25M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21415068915.207.8085002.06EPA 3401924
EA*5X25M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21415069715.207.8084002.04EPA 3401931

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.