H5H3V48*K*AAA*
Deluxe 23 VS Heat Pump · source records, page 3
138 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H3V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 138 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19.5–23 | 138 / 138 |
| EER2 · BTU/Wh | 10–12.5 | 138 / 138 |
| HSPF2 · BTU/Wh | 8–9.5 | 138 / 138 |
| Cooling capacity · BTU/h | 43,000–46,500 | 138 / 138 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,000–53,500 | 135 / 138 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 39,000–43,500 | 138 / 138 |
| Heating capacity at 5°F / −15°C · BTU/h | 35,600–38,500 | 138 / 138 |
| COP at 5°F / −15°C | 1.8–2 | 138 / 138 |
| Equipment / loop type | HP - Split System | 138 / 138 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 138 / 138 |
| Compressor staging | Continuously variable | 138 / 138 |
| Connected capability | No | 138 / 138 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215934098 | 21.00 | 9.50 | 36600 | 2.00 | EPA 3732344 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215937488 | 21.00 | 8.10 | 38000 | 1.95 | EPA 3732373 → |
EVD5X60M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215938298 | 21.00 | 8.10 | 38000 | 1.95 | EPA 3734238 → |
EVD5X60M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215938308 | 21.00 | 8.10 | 38000 | 1.95 | EPA 3734249 → |
EVD5X60M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215938318 | 21.00 | 8.10 | 38000 | 1.95 | EPA 3734259 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215940998 | 21.00 | 9.50 | 36600 | 2.00 | EPA 3734329 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215941008 | 21.00 | 9.50 | 36600 | 2.00 | EPA 3734338 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215941018 | 21.00 | 9.50 | 36400 | 2.00 | EPA 3734348 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215941028 | 21.00 | 9.50 | 36400 | 2.00 | EPA 3734358 → |
EA*5X61M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215941038 | 21.00 | 9.50 | 37000 | 2.00 | EPA 3734368 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215941058 | 21.00 | 9.50 | 37000 | 2.00 | EPA 3735539 → |
EA*5X61M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215941078 | 21.00 | 9.50 | 37000 | 2.00 | EPA 3735558 → |
EA*5X61M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215941088 | 21.00 | 9.50 | 36800 | 2.00 | EPA 3735569 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215941098 | 21.00 | 9.50 | 37000 | 2.00 | EPA 3735579 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215941108 | 21.00 | 9.50 | 37000 | 2.00 | EPA 3735822 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215940988 | 21.00 | 9.50 | 36400 | 2.00 | EPA 3735984 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215940948 | 21.00 | 9.50 | 36400 | 1.92 | EPA 3736262 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215940958 | 21.00 | 9.50 | 36600 | 1.90 | EPA 3736272 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215934398 | 21.00 | 9.50 | 36800 | 1.92 | EPA 4012308 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215934308 | 21.00 | 9.50 | 37000 | 1.90 | EPA 4012331 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →