H5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 8
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X61M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215682467 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3977422 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215682477 | 19.00 | 9.00 | 36800 | 2.12 | EPA 3977424 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682497 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3977452 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215682517 | 19.00 | 9.50 | 36800 | 2.10 | EPA 3977463 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215682527 | 19.00 | 9.00 | 36400 | 2.12 | EPA 3977472 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215682537 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3977486 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682547 | 19.00 | 9.50 | 36800 | 2.10 | EPA 3977496 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215674488 | 18.50 | 9.00 | 33600 | 2.08 | EPA 3968234 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215674498 | 18.50 | 9.00 | 33600 | 2.08 | EPA 3968245 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215674508 | 18.50 | 9.00 | 33600 | 2.08 | EPA 3968257 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215674602 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968303 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215674644 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968318 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215674667 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968329 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215674368 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968614 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215674378 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968625 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215675827 | 18.50 | 9.00 | 36200 | 2.02 | EPA 3968819 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215675857 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3968856 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215675687 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3968955 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215675707 | 18.50 | 9.00 | 37200 | 2.00 | EPA 3968977 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215675367 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969039 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →