H5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 18
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X48M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215674942 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968420 → |
ESH5X48M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215675103 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968522 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215675121 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968689 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215675147 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968703 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215675187 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968734 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215675197 | 16.50 | 8.50 | 34000 | 2.06 | EPA 3968743 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675207 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968756 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675217 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968758 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215675227 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968777 → |
ESH5X60M12A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215675247 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968787 → |
ESH5X60M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215675257 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968875 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215675287 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968899 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215675297 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968915 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215675307 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968924 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215675327 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968934 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215675337 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3969012 → |
ESH5X48M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681587 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3975294 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215681667 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3975324 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681677 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3975400 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681707 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3975430 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →