H5H0V48*K*AAA*
Deluxe 20 VS Heat Pump
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 215675347 | 19.50 | 9.50 | 33000 | 2.20 | EPA 3969016 → |
EVM5X61M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215675957 | 19.50 | 9.00 | 36600 | 2.10 | EPA 3969465 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675987 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969498 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675997 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969510 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215676007 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3969517 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676057 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970011 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215676067 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970018 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676077 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970028 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215676087 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970045 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215676747 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970411 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215676757 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3970429 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676817 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970572 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676837 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3970588 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215676847 | 19.50 | 9.00 | 36600 | 2.10 | EPA 3970605 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215676877 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3970796 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215676887 | 19.50 | 9.50 | 36600 | 2.10 | EPA 3970812 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215676927 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971335 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215676937 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971347 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215676947 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3971353 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215676957 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3971367 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →