D5CUHAH36AAK+KSAIC0701230
Crossover Heat Pump · source records, page 14
316 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH36AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 316 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 316 / 316 |
| EER2 · BTU/Wh | 9.4–10.5 | 316 / 316 |
| HSPF2 · BTU/Wh | 8.1–9 | 316 / 316 |
| Cooling capacity · BTU/h | 34,200–38,000 | 316 / 316 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 316 / 316 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 316 / 316 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 316 / 316 |
| COP at 5°F / −15°C | 1.75–1.9 | 316 / 316 |
| Equipment / loop type | HP - Split System | 316 / 316 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 316 / 316 |
| Compressor staging | Continuously variable | 316 / 316 |
| Connected capability | No | 316 / 316 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X42M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 218495380 | 15.50 | 8.50 | 30800 | 1.78 | EPA 4637761 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 218495373 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637768 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218495345 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4637775 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218495338 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637782 → |
EA*5X42M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218495331 | 15.50 | 8.50 | 30800 | 1.80 | EPA 4637789 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218495324 | 15.50 | 8.50 | 30200 | 1.82 | EPA 4637796 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218495282 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637817 → |
EA*5X42M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218495275 | 15.50 | 8.50 | 30800 | 1.78 | EPA 4637824 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218495268 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637831 → |
EA*5X48M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218516542 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638267 → |
EA*5X48M21A*+ furnace: *92MSN0601714A*Cold climate designationAHRI reference: 218516521 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638288 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 218516514 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638295 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218516507 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638302 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0701716A*Cold climate designationAHRI reference: 218516500 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638309 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218516493 | 15.50 | 8.10 | 30000 | 1.75 | EPA 4638316 → |
ESH5X36M12A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218492873 | 15.20 | 8.10 | 30800 | 1.75 | EPA 4635007 → |
ESH5X36M12A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218492831 | 15.20 | 8.10 | 30800 | 1.75 | EPA 4635028 → |
ESH5X36M12A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 218492789 | 15.20 | 8.10 | 30800 | 1.75 | EPA 4635049 → |
ESH5X36M12A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 218492761 | 15.20 | 8.10 | 30800 | 1.75 | EPA 4635056 → |
ESH5X36M12A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218492670 | 15.20 | 8.10 | 30600 | 1.75 | EPA 4635105 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →