Arcoaire / AIR-SOURCE HEAT PUMP

D5CUHAH30AAK+KSAIC0701230

Crossover Heat Pump

336 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8.1–9BTU/Wh
Cooling capacity28,600–31,200BTU/h

Each efficiency range summarizes published EPA records for D5CUHAH30AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 336 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17336 / 336
EER2 · BTU/Wh9.5–10.5336 / 336
HSPF2 · BTU/Wh8.1–9336 / 336
Cooling capacity · BTU/h28,600–31,200336 / 336
Heating capacity at 47°F / 8.3°C · BTU/h35,800–37,400336 / 336
Heating capacity at 17°F / −8.3°C · BTU/h20,800–21,600336 / 336
Heating capacity at 5°F / −15°C · BTU/h32,000–33,400336 / 336
COP at 5°F / −15°C1.75–2336 / 336
Equipment / loop typeHP - Split System336 / 336
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)336 / 336
Compressor stagingContinuously variable336 / 336
Connected capabilityNo336 / 336

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B36L0C*Cold climate designationAHRI reference: 21847540317.008.50328001.78EPA 4626394
EA*5X43M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21849010117.009.00320001.98EPA 4633504
EA*5X37M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21849086317.009.00320001.98EPA 4634024
FMA5X30**AL*Cold climate designationAHRI reference: 21848847816.509.00320001.92EPA 4632510
FMA5X36**AL*Cold climate designationAHRI reference: 21848847116.509.00320001.92EPA 4632517
EA*5X43M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21849011516.509.00322001.96EPA 4633490
EA*5X43M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21849009416.509.00322001.96EPA 4633511
EA*5X43M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 21849008716.509.00322001.98EPA 4633518
EA*5X43M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 21849008016.509.00322001.98EPA 4633525
EA*5X43M21A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 21849006616.509.00322001.96EPA 4633539
EA*5X37M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 21849111016.509.00322001.96EPA 4633777
EA*5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21849110316.509.00322001.96EPA 4633784
EA*5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 21849109616.509.00322001.96EPA 4633791
EA*5X37M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 21849107516.509.00322001.96EPA 4633812
EA*5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21849106816.509.00322001.96EPA 4633819
EA*5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 21849106116.509.00322001.96EPA 4633826
EA*5X37M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21849103316.509.00322001.98EPA 4633854
EA*5X37M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21849102616.509.00322001.98EPA 4633861
EA*5X37M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21849099816.509.00322001.98EPA 4633889
EA*5X37M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21849099116.509.00322001.96EPA 4633896

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →