Heating performance & equipment details
Ranges include the 499 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 499 / 499 |
| EER2 · BTU/Wh | 10–11 | 499 / 499 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 499 / 499 |
| Cooling capacity · BTU/h | 22,600–25,000 | 499 / 499 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 499 / 499 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 499 / 499 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 499 / 499 |
| COP at 5°F / −15°C | 1.85–2.06 | 499 / 499 |
| Equipment / loop type | HP - Split System | 499 / 499 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 499 / 499 |
| Compressor staging | Continuously variable | 499 / 499 |
| Connected capability | No | 499 / 499 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X36M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218487014 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631181 → |
EA*5X36M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218487007 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631188 → |
EA*5X36M17A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 218487000 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631195 → |
EA*5X36M17A*+ furnace: *96VTN0401410B*Cold climate designationAHRI reference: 218486993 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631202 → |
EA*5X36M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218486979 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631216 → |
EA*5X36M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218486965 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631230 → |
EA*5X36M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 218486958 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631237 → |
EA*5X36M17A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 218486951 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4631244 → |
EA*5X36M17A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 218486944 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631251 → |
EA*5X30M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218486881 | 16.50 | 8.50 | 19700 | 1.90 | EPA 4631314 → |
EA*5X30M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218486860 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631335 → |
EA*5X30M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218486853 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631342 → |
EA*5X30M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218486846 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631349 → |
EA*5X30M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218486839 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631356 → |
EA*5X30M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218486832 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631363 → |
EA*5X30M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218486804 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631391 → |
EA*5X30M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218486797 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631398 → |
EA*5X30M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218486790 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631405 → |
EA*5X30M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 218486783 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4631412 → |
EA*5X30M14A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218486706 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631489 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.