SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity22,600–25,000BTU/h

Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 499 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18499 / 499
EER2 · BTU/Wh10–11499 / 499
HSPF2 · BTU/Wh8.1–9.5499 / 499
Cooling capacity · BTU/h22,600–25,000499 / 499
Heating capacity at 47°F / 8.3°C · BTU/h22,200–25,800499 / 499
Heating capacity at 17°F / −8.3°C · BTU/h16,800–18,700499 / 499
Heating capacity at 5°F / −15°C · BTU/h18,700–20,600499 / 499
COP at 5°F / −15°C1.85–2.06499 / 499
Equipment / loop typeHP - Split System499 / 499
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)499 / 499
Compressor stagingContinuously variable499 / 499
Connected capabilityNo499 / 499

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X24**AL*Cold climate designationAHRI reference: 21848625817.509.00190002.02EPA 4631937 →
FM(C,U)5Z36**AL*Cold climate designationAHRI reference: 21848623717.509.00190002.04EPA 4631944 →
FM(C,U)5Z30**AL*Cold climate designationAHRI reference: 21848623017.509.00190002.04EPA 4631951 →
EA*5X25M17A*+ furnace: *80MS(N,L)0701412A*Cold climate designationAHRI reference: 21848481317.008.50189001.94EPA 4629415 →
EA*5X36M17A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 21848511117.008.50193001.92EPA 4629638 →
EA*5X25M17A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 21848486917.008.50189001.94EPA 4629857 →
EA*5X37M21A*+ furnace: *92MSN1002120A*Cold climate designationAHRI reference: 21848541617.008.50188001.92EPA 4630229 →
EA*5X37M21A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 21848540217.008.50187001.94EPA 4630243 →
EA*5X37M21A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 21848533917.008.50188001.94EPA 4630306 →
EA*5X37M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 21848745517.009.00189002.02EPA 4630740 →
EA*5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21848744817.008.50187001.92EPA 4630747 →
EA*5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 21848744117.008.50189001.92EPA 4630754 →
EA*5X37M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 21848743417.009.00189002.02EPA 4630761 →
EA*5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 21848742717.008.50188001.92EPA 4630768 →
EA*5X37M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 21848742017.009.00189002.02EPA 4630775 →
EA*5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21848741317.008.50187001.92EPA 4630782 →
EA*5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 21848740617.008.50189001.92EPA 4630789 →
EA*5X37M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 21848739917.009.00189002.02EPA 4630796 →
EA*5X37M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 21848739217.008.50188001.92EPA 4630803 →
EA*5X37M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21848736417.008.50187001.92EPA 4630831 →