B5H6S36*K*AAA*
MAINLINE 16 SEER2 HP
26 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H6S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 26 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–15.5 | 26 / 26 |
| EER2 · BTU/Wh | 11.7–13 | 26 / 26 |
| HSPF2 · BTU/Wh | 7.8 | 26 / 26 |
| Cooling capacity · BTU/h | 33,800–36,800 | 26 / 26 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,200 | 26 / 26 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 26 / 26 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,700–18,100 | 26 / 26 |
| COP at 5°F / −15°C | 2–2.24 | 26 / 26 |
| Equipment / loop type | HP - Split System | 26 / 26 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 26 / 26 |
| Compressor staging | Single stage | 26 / 26 |
| Connected capability | No | 26 / 26 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 218193510 | 15.50 | 7.80 | 17400 | 2.22 | EPA 4582114 → |
F5MA5*48L*C*AHRI reference: 218193504 | 15.50 | 7.80 | 17500 | 2.24 | EPA 4582116 → |
FMA5X36**AL*AHRI reference: 218192801 | 15.50 | 7.80 | 17000 | 2.00 | EPA 4582250 → |
FEVB0048**+NAVA54801CKAHRI reference: 218192791 | 15.50 | 7.80 | 17400 | 2.22 | EPA 4582252 → |
FHMA5*48L*C*AHRI reference: 218192497 | 15.50 | 7.80 | 17500 | 2.24 | EPA 4582254 → |
FTMA5B48L0C*AHRI reference: 218192486 | 15.50 | 7.80 | 16700 | 2.18 | EPA 4582257 → |
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 218191391 | 15.20 | 7.80 | 17500 | 2.20 | EPA 4582050 → |
EA*5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 218191383 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4582053 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 218191381 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4582055 → |
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 218191363 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4582058 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 218191350 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4582061 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 218191347 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4582064 → |
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 218191340 | 15.20 | 7.80 | 17300 | 2.20 | EPA 4582066 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 218191337 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4582069 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 218191328 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4582072 → |
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 218191322 | 15.20 | 7.80 | 17600 | 2.20 | EPA 4582075 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 218191319 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4582078 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 218191290 | 15.20 | 7.80 | 17900 | 2.20 | EPA 4582081 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 218191271 | 15.20 | 7.80 | 18000 | 2.20 | EPA 4582084 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 218191268 | 15.20 | 7.80 | 17900 | 2.20 | EPA 4582087 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →