B5H6S31*K*AAA*
MAINLINE 16 SEER2 HP
38 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H6S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 38 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 38 / 38 |
| EER2 · BTU/Wh | 11.7–13 | 38 / 38 |
| HSPF2 · BTU/Wh | 7.8–8 | 38 / 38 |
| Cooling capacity · BTU/h | 27,400–29,400 | 38 / 38 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,200–30,600 | 38 / 38 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,300–18,200 | 38 / 38 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,100–14,000 | 38 / 38 |
| COP at 5°F / −15°C | 2–2.06 | 38 / 38 |
| Equipment / loop type | HP - Split System | 38 / 38 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 38 / 38 |
| Compressor staging | Single stage | 38 / 38 |
| Connected capability | No | 38 / 38 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FMA5X36**AL*AHRI reference: 218210719 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4584235 → |
FMA5X30**AL*AHRI reference: 218210717 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4584237 → |
FM(C,U)5Z36**AL*AHRI reference: 218210711 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4584241 → |
FM(C,U)5Z30**AL*AHRI reference: 218210709 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4584243 → |
F5MA5*42L*C*AHRI reference: 218210703 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4584245 → |
FHMA5*42L*C*AHRI reference: 218210702 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4584246 → |
FHMA5*30L*B*AHRI reference: 218201234 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4583714 → |
EA*5X37M21A*+ furnace: *92MSN1002122A*AHRI reference: 218203430 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4583723 → |
EA*5X37M21A*+ furnace: *92MSN1002120A*AHRI reference: 218203426 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4583725 → |
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 218203424 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4583727 → |
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 218203378 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4583729 → |
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 218203376 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4583731 → |
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 218203372 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4583733 → |
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 218203364 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4583735 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 218203360 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4583737 → |
EA*5X37M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 218203342 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4583739 → |
EA*5X37M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 218203338 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4583741 → |
EA*5X43M21A*+ furnace: *97VTN1002122A*AHRI reference: 218209946 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584155 → |
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 218209936 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584157 → |
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 218209910 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4584159 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →