A5HP5042A1
A5HP5
125 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A5HP5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 125 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 125 / 125 |
| EER2 · BTU/Wh | 11.7–12 | 125 / 125 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 125 / 125 |
| Cooling capacity · BTU/h | 37,800–41,500 | 125 / 125 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,500 | 125 / 125 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,800–26,400 | 125 / 125 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,800–20,000 | 125 / 125 |
| COP at 5°F / −15°C | 2–2.3 | 125 / 125 |
| Equipment / loop type | HP - Split System | 125 / 125 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 125 / 125 |
| Compressor staging | Single stage | 125 / 125 |
| Connected capability | No | 125 / 125 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCC007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 214296567 | 16.00 | 8.10 | 19500 | 2.10 | EPA 3424330 → |
5TXCC007AS3+TSTAT+ furnace: A952V100CU5SBAHRI reference: 214296569 | 16.00 | 8.10 | 19700 | 2.10 | EPA 3424331 → |
5TXCC007AS3+TSTAT+ furnace: A952V100CU5SAAHRI reference: 214296571 | 16.00 | 8.10 | 19700 | 2.10 | EPA 3424333 → |
5TXCC007AS3+TSTAT+ furnace: A952V080CU5SBAHRI reference: 214296573 | 16.00 | 8.10 | 19700 | 2.10 | EPA 3424335 → |
5TXCC007AS3+TSTAT+ furnace: A952V080CU5SAAHRI reference: 214296575 | 16.00 | 8.10 | 19200 | 2.10 | EPA 3424336 → |
5TXCD010AS3+TSTAT+ furnace: A952V120DU5SAAHRI reference: 214296595 | 16.00 | 8.10 | 18900 | 2.20 | EPA 3424356 → |
5TXCD010AS3+TSTAT+ furnace: A952V120DU5SBAHRI reference: 214296597 | 16.00 | 8.10 | 19400 | 2.10 | EPA 3424359 → |
A5AHV004A1D3+TDR+TSTATAHRI reference: 214296607 | 16.00 | 8.10 | 19100 | 2.20 | EPA 3424369 → |
A5AHV006A1D3+TDR+TSTATAHRI reference: 214296609 | 16.00 | 8.10 | 19400 | 2.20 | EPA 3424370 → |
A5AHV007A1D3+TDR+TSTATAHRI reference: 214296611 | 16.00 | 8.10 | 19400 | 2.20 | EPA 3424372 → |
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 215575269 | 16.00 | 7.80 | 19400 | 2.10 | EPA 3651650 → |
A5AHV005A1D3+TDR+TSTATAHRI reference: 215611107 | 16.00 | 8.10 | 19100 | 2.20 | EPA 3651687 → |
5TXCC009AS3+TSTAT+ furnace: A801X080CM5TDAHRI reference: 215575503 | 16.00 | 8.10 | 19200 | 2.20 | EPA 3651717 → |
5TXCC009AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 215575505 | 16.00 | 8.10 | 19500 | 2.10 | EPA 3651719 → |
5TXCC009AS3+TSTAT+ furnace: A952V100CU5SBAHRI reference: 215575507 | 16.00 | 8.10 | 19200 | 2.20 | EPA 3651721 → |
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 215575509 | 16.00 | 8.10 | 19100 | 2.20 | EPA 3651723 → |
5TXCD008AS3+TSTAT+P0V0D000M50SDAHRI reference: 215575517 | 16.00 | 8.10 | 19200 | 2.10 | EPA 3651727 → |
5TXCD008AS3+TSTAT+ furnace: A952V120DU5SBAHRI reference: 215575519 | 16.00 | 8.10 | 19500 | 2.10 | EPA 3651729 → |
5TXCD008AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 215575521 | 16.00 | 8.10 | 19300 | 2.10 | EPA 3651731 → |
5TXCD008AS3+TSTAT+ furnace: A801X120DM5TDAHRI reference: 215575523 | 16.00 | 8.10 | 19600 | 2.10 | EPA 3651733 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →