Ameristar / AIR-SOURCE HEAT PUMP

A5HP5036A1

A5HP5 · source records, page 7

148 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity32,000–35,200BTU/h

Each efficiency range summarizes published EPA records for A5HP5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 148 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16148 / 148
EER2 · BTU/Wh11.7–12148 / 148
HSPF2 · BTU/Wh7.8–8.5148 / 148
Cooling capacity · BTU/h32,000–35,200148 / 148
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800148 / 148
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400148 / 148
Heating capacity at 5°F / −15°C · BTU/h16,700–17,800148 / 148
COP at 5°F / −15°C2.1–2.4148 / 148
Equipment / loop typeHP - Split System148 / 148
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)148 / 148
Compressor stagingSingle stage148 / 148
Connected capabilityNo148 / 148

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B004AS3+TSTAT+ furnace: A952V080BU4SBAHRI reference: 21557494915.208.10174002.20EPA 3651348
5PX*B004AS3+TSTAT+P0V0B000M40SDAHRI reference: 21557495115.207.80172002.30EPA 3651350
5PX*B004AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21557495915.207.80173002.20EPA 3651351
5PX*B004AS3+TSTAT+ furnace: A801X080BM4TDAHRI reference: 21557496915.207.80174002.20EPA 3651355
5PX*B004AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21557497115.207.80174002.20EPA 3651356
5PX*B004AS3+TSTAT+ furnace: A801X060BM4TDAHRI reference: 21557497315.208.10173002.20EPA 3651358
5PX*B004AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21557497515.208.10173002.20EPA 3651360
5PX*B006AS3+TSTAT+ furnace: L9X1B070U4VSAAHRI reference: 21557498115.208.10176002.20EPA 3651363
5PX*B006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21557498515.207.80168002.20EPA 3651366
5PX*C009AS3+TSTAT+ furnace: L9X1C100U5VSAAHRI reference: 21557512915.208.10175002.20EPA 3651426
5PX*CD05AS3+TSTAT+ furnace: A801X080CM5TDAHRI reference: 21557513715.207.80177002.10EPA 3651430
5PX*CD05AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21557513915.207.80177002.10EPA 3651432
5PX*CD05AS3+TSTAT+P0V0C000M50SDAHRI reference: 21557514315.207.80175002.20EPA 3651434
5TXCB003AS3+TSTAT+P0V0B000M40SDAHRI reference: 21557518115.207.80177002.10EPA 3651497
5TXCB003AS3+TSTAT+ furnace: A801X060BM4TDAHRI reference: 21557518715.207.80178002.10EPA 3651499
5TXCB003AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21557518915.207.80178002.10EPA 3651501
5TXCC005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21557520715.208.10174002.20EPA 3651503
5TXCC005AS3+TSTAT+ furnace: A952V100CU5SBAHRI reference: 21557520915.208.10175002.20EPA 3651505
5TXCC005AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21557521115.208.10173002.20EPA 3651507
5TXCC005AS3+TSTAT+ furnace: A801X080CM5TDAHRI reference: 21557521315.208.10175002.20EPA 3651509