Ameristar / AIR-SOURCE HEAT PUMP

A5HP5030A1

A5HP5 · source records, page 2

41 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,800–29,000BTU/h

Each efficiency range summarizes published EPA records for A5HP5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 41 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1641 / 41
EER2 · BTU/Wh11.7–1241 / 41
HSPF2 · BTU/Wh7.8–8.141 / 41
Cooling capacity · BTU/h26,800–29,00041 / 41
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,40041 / 41
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,60041 / 41
Heating capacity at 5°F / −15°C · BTU/h12,700–13,70041 / 41
COP at 5°F / −15°C2–2.241 / 41
Equipment / loop typeHP - Split System41 / 41
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)41 / 41
Compressor stagingSingle stage41 / 41
Connected capabilityNo41 / 41

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21429634915.207.80130002.00EPA 3423768 →
5TXCB006AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 21429635315.208.10136002.10EPA 3423769 →
5TXCB006AS3+TSTAT+ furnace: A952V060BU4SAAHRI reference: 21429635515.208.10134002.10EPA 3423771 →
5TXCB006AS3+TSTAT+ furnace: A952V040BU3SBAHRI reference: 21429635715.208.10134002.10EPA 3423774 →
5TXCB006AS3+TSTAT+ furnace: A801X080BM4TDAHRI reference: 21429636115.207.80135002.10EPA 3423777 →
5TXCB006AS3+TSTAT+ furnace: A952V040BU3SAAHRI reference: 21429635915.208.10133002.10EPA 3423778 →
5TXCB006AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21429636315.207.80135002.10EPA 3423781 →
5TXCB004AS3+TSTAT+ furnace: A801X060BM4TDAHRI reference: 21429628315.207.80135002.00EPA 3424701 →
5TXCB004AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21429629515.207.80135002.00EPA 3424703 →
5TXCB004AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21429630515.207.80137002.00EPA 3424707 →
5PX*B006AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 21557473715.208.10137002.10EPA 3650669 →
5PX*B006AS3+TSTAT+ furnace: A952V040BU3SBAHRI reference: 21557473915.208.10137002.10EPA 3650672 →
5PX*C007AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21557483915.207.80134002.10EPA 3651120 →
5PX*CD07AS3+TSTAT+ furnace: A801X080CM5TDAHRI reference: 21557484715.207.80135002.10EPA 3651122 →
5PX*CD07AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21557484915.207.80135002.10EPA 3651124 →
5PX*C007AS3+TSTAT+ furnace: A801X080CM5TDAHRI reference: 21557483515.207.80134002.10EPA 3651163 →
A5AHC003A1B3+TDR+TSTATAHRI reference: 21561107515.208.10134002.20EPA 3651531 →
A5AHC004A1D3+TDR+TSTATAHRI reference: 21561107715.208.10134002.10EPA 3651533 →
A5AHC005A1D3+TDR+TSTATAHRI reference: 21561107915.208.10133002.10EPA 3651535 →
A5AHC006A1D3+TDR+TSTATAHRI reference: 21561108115.208.10134002.20EPA 3651537 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →