A5HP5024A1
A5HP5 · source records, page 2
36 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A5HP5024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 36 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 36 / 36 |
| EER2 · BTU/Wh | 11.7–12 | 36 / 36 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 36 / 36 |
| Cooling capacity · BTU/h | 21,200–24,400 | 36 / 36 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 20,600–23,000 | 36 / 36 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,700–15,300 | 36 / 36 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,600–11,800 | 36 / 36 |
| COP at 5°F / −15°C | 1.9–2.1 | 36 / 36 |
| Equipment / loop type | HP - Split System | 36 / 36 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 36 / 36 |
| Compressor staging | Single stage | 36 / 36 |
| Connected capability | No | 36 / 36 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCB004AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 214296213 | 15.20 | 7.80 | 11000 | 2.00 | EPA 3423639 → |
5TXCB004AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 214296215 | 15.20 | 7.80 | 11100 | 2.00 | EPA 3423641 → |
5TXCB004AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 214296217 | 15.20 | 7.80 | 11400 | 2.00 | EPA 3423643 → |
5TXCB004AS3+TSTAT+ furnace: L9X1A050U3VSAAHRI reference: 214296219 | 15.20 | 7.80 | 10600 | 1.90 | EPA 3423645 → |
5TXCB004AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 214296227 | 15.20 | 7.80 | 11300 | 2.00 | EPA 3423649 → |
5TXCB004AS3+TSTAT+ furnace: A801X060BM4TDAHRI reference: 214296229 | 15.20 | 7.80 | 11300 | 2.00 | EPA 3423651 → |
5TXCB004AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 214296231 | 15.20 | 7.80 | 11300 | 2.00 | EPA 3423653 → |
5TXCB004AS3+TSTAT+ furnace: A801X040BM2TDAHRI reference: 214296233 | 15.20 | 7.80 | 11200 | 2.00 | EPA 3424567 → |
5TXCB004AS3+TSTAT+ furnace: A801X040BM2SDAHRI reference: 214296235 | 15.20 | 7.80 | 11200 | 2.00 | EPA 3424569 → |
5TXCB004AS3+TSTAT+ furnace: A801X040AM3TDAHRI reference: 214296237 | 15.20 | 7.80 | 10900 | 2.00 | EPA 3424571 → |
5TXCB004AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 214296239 | 15.20 | 7.80 | 10900 | 2.00 | EPA 3424573 → |
A5AHV003A1B3+TDR+TSTATAHRI reference: 214296265 | 15.20 | 8.10 | 11800 | 2.10 | EPA 3424592 → |
A5AHC002A1B3+TDR+TSTATAHRI reference: 215611065 | 15.20 | 7.80 | 11200 | 2.10 | EPA 3651521 → |
A5AHC003A1B3+TDR+TSTATAHRI reference: 215611067 | 15.20 | 8.10 | 11400 | 2.10 | EPA 3651523 → |
A5AHC004A1D3+TDR+TSTATAHRI reference: 215611069 | 15.20 | 8.10 | 11100 | 2.10 | EPA 3651525 → |
A5AHV002A1B3+TDR+TSTATAHRI reference: 215611071 | 15.20 | 8.10 | 11300 | 2.10 | EPA 3651527 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →