Ameristar / AIR-SOURCE HEAT PUMP

A5HL5036A1

A5HL5 · source records, page 2

30 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range8.1BTU/Wh
Cooling capacity33,000–34,000BTU/h

Each efficiency range summarizes published EPA records for A5HL5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 30 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1630 / 30
EER2 · BTU/Wh11–11.730 / 30
HSPF2 · BTU/Wh8.130 / 30
Cooling capacity · BTU/h33,000–34,00030 / 30
Heating capacity at 47°F / 8.3°C · BTU/h34,000–35,00030 / 30
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,00030 / 30
Heating capacity at 5°F / −15°C · BTU/h27,000–30,00030 / 30
COP at 5°F / −15°C1.75–1.830 / 30
Equipment / loop typeHP - Split System30 / 30
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)30 / 30
Compressor stagingTwo-stage30 / 30
Connected capabilityNo30 / 30

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+ furnace: A801X060BM4TDCold climate designationAHRI reference: 21719485115.208.10300001.80EPA 4011201
5TXCB006AS3+ furnace: A801X080BM4TDCold climate designationAHRI reference: 21719485215.208.10300001.80EPA 4011202
5TXCB006AS3+ furnace: A951X060BU4SACold climate designationAHRI reference: 21719486115.208.10300001.80EPA 4011278
5TXCB006AS3+ furnace: A951X080BU4SACold climate designationAHRI reference: 21719486315.208.10300001.80EPA 4011279
5TXCC007AS3+ furnace: A951X080CU5SACold climate designationAHRI reference: 21719486415.208.10300001.80EPA 4011280
5TXCC007AS3+ furnace: A951X100CU5SACold climate designationAHRI reference: 21719486615.208.10300001.80EPA 4011281
5TXCD008AS3+ furnace: S9X1D120D5PSBCold climate designationAHRI reference: 21719486715.208.10290001.80EPA 4011282
5TXCC007AS3+ furnace: A951X100CD5SACold climate designationAHRI reference: 21719486515.208.10300001.80EPA 4011394
5TXCC007AS3+ furnace: A801X080CM5SDCold climate designationAHRI reference: 21719485315.208.10300001.80EPA 4011395
5TXCB006AS3+ furnace: A951X080BD4SACold climate designationAHRI reference: 21719486215.208.10300001.80EPA 4011410

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →