N5HP5048A1
Bronze 15
28 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5HP5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 28 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 28 / 28 |
| EER2 · BTU/Wh | 11.7–12 | 28 / 28 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 28 / 28 |
| Cooling capacity · BTU/h | 43,500–45,500 | 28 / 28 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 41,500–42,500 | 28 / 28 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,600–29,000 | 28 / 28 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,000–22,400 | 28 / 28 |
| COP at 5°F / −15°C | 2.14–2.27 | 28 / 28 |
| Equipment / loop type | HP - Split System | 28 / 28 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 28 / 28 |
| Compressor staging | Single stage | 28 / 28 |
| Connected capability | No | 28 / 28 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
A5AHV007A1D3+TDR+TSTATAHRI reference: 218470568 | 16.00 | 8.10 | 22200 | 2.26 | EPA 4621408 → |
A5AHV006A1D3+TDR+TSTATAHRI reference: 218470567 | 16.00 | 8.10 | 22200 | 2.26 | EPA 4621409 → |
5TXCD010AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 218470565 | 16.00 | 8.10 | 22200 | 2.21 | EPA 4621411 → |
5TXCD010AS3+TSTAT+P0V0C000M50SDAHRI reference: 218470563 | 16.00 | 8.10 | 22000 | 2.22 | EPA 4621413 → |
5TXCD010AS3+TSTAT+P0V0D000M50SDAHRI reference: 218470562 | 16.00 | 8.10 | 22200 | 2.24 | EPA 4621414 → |
5TXCD010AS3+TSTAT+ furnace: A801X120DM5SDAHRI reference: 218470561 | 16.00 | 8.10 | 22200 | 2.19 | EPA 4621415 → |
5TXCD010AS3+TSTAT+ furnace: A952V120DU5SBAHRI reference: 218470559 | 16.00 | 8.10 | 22200 | 2.21 | EPA 4621417 → |
5PX*D010AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 218470538 | 16.00 | 8.10 | 22200 | 2.21 | EPA 4621421 → |
5PX*D010AS3+TSTAT+ furnace: A952V120DU5SBAHRI reference: 218470537 | 16.00 | 8.10 | 22200 | 2.21 | EPA 4621422 → |
5PX*D010AS3+TSTAT+ furnace: A801X120DM5SDAHRI reference: 218470535 | 16.00 | 8.10 | 22200 | 2.19 | EPA 4621424 → |
5PX*D010AS3+TSTAT+P0V0D000M50SDAHRI reference: 218470533 | 16.00 | 8.10 | 22200 | 2.24 | EPA 4621426 → |
5PX*D010AS3+TSTAT+P0V0C000M50SDAHRI reference: 218470532 | 16.00 | 8.10 | 22000 | 2.22 | EPA 4621427 → |
5PX*D008AS3+TSTAT+P0V0D000M50SDAHRI reference: 218470525 | 16.00 | 8.10 | 22200 | 2.16 | EPA 4621429 → |
5PX*D008AS3+TSTAT+P0V0C000M50SDAHRI reference: 218470524 | 16.00 | 8.10 | 22200 | 2.15 | EPA 4621430 → |
5TXCD010AS3+TSTAT+ furnace: A952V100CU5SBAHRI reference: 218470564 | 15.50 | 8.10 | 22200 | 2.19 | EPA 4621412 → |
5TXCD010AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 218470560 | 15.50 | 7.80 | 22000 | 2.18 | EPA 4621416 → |
5TXCC009AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 218470550 | 15.50 | 8.00 | 22400 | 2.17 | EPA 4621418 → |
5TXCC009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 218470549 | 15.50 | 7.80 | 22000 | 2.17 | EPA 4621419 → |
5PX*D010AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 218470536 | 15.50 | 7.80 | 22000 | 2.18 | EPA 4621423 → |
5PX*D010AS3+TSTAT+ furnace: A952V100CU5SBAHRI reference: 218470534 | 15.50 | 8.10 | 22200 | 2.19 | EPA 4621425 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.