N5HP5042A1
Bronze 15
72 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5HP5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 72 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 72 / 72 |
| EER2 · BTU/Wh | 11.7–12 | 72 / 72 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 72 / 72 |
| Cooling capacity · BTU/h | 38,000–41,000 | 72 / 72 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,600–39,000 | 72 / 72 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–26,200 | 72 / 72 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–19,900 | 72 / 72 |
| COP at 5°F / −15°C | 2.11–2.28 | 72 / 72 |
| Equipment / loop type | HP - Split System | 72 / 72 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 72 / 72 |
| Compressor staging | Single stage | 72 / 72 |
| Connected capability | No | 72 / 72 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCD008AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 218470734 | 16.00 | 8.10 | 19400 | 2.18 | EPA 4621389 → |
A5AHV006A1D3+TDR+TSTATAHRI reference: 218470505 | 16.00 | 8.10 | 19400 | 2.24 | EPA 4621434 → |
5TXCD010AS3+TSTAT+ furnace: A801X120DM5SDAHRI reference: 218470496 | 16.00 | 8.10 | 19400 | 2.22 | EPA 4621440 → |
5TXCD010AS3+TSTAT+ furnace: A952V120DU5SBAHRI reference: 218470494 | 16.00 | 8.10 | 19200 | 2.23 | EPA 4621442 → |
5TXCD010AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 218470493 | 16.00 | 8.10 | 19300 | 2.23 | EPA 4621443 → |
5TXCD010AS3+TSTAT+P0V0D000M50SDAHRI reference: 218470492 | 16.00 | 8.10 | 19200 | 2.24 | EPA 4621444 → |
5TXCD008AS3+TSTAT+P0V0D000M50SDAHRI reference: 218470491 | 16.00 | 8.10 | 19300 | 2.20 | EPA 4621445 → |
5TXCD008AS3+TSTAT+ furnace: A801X120DM5SDAHRI reference: 218470490 | 16.00 | 8.10 | 19500 | 2.17 | EPA 4621446 → |
5TXCD008AS3+TSTAT+ furnace: A952V120DU5SBAHRI reference: 218470489 | 16.00 | 8.10 | 19300 | 2.21 | EPA 4621447 → |
5TXCC009AS3+TSTAT+P0V0C000M50SDAHRI reference: 218470482 | 16.00 | 8.10 | 19200 | 2.22 | EPA 4621448 → |
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 218470481 | 16.00 | 8.10 | 19300 | 2.22 | EPA 4621449 → |
5TXCC007AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 218470478 | 16.00 | 8.10 | 19400 | 2.17 | EPA 4621450 → |
5TXCC007AS3+TSTAT+ furnace: A952V080CU5SBAHRI reference: 218470476 | 16.00 | 8.10 | 19500 | 2.17 | EPA 4621452 → |
5TXCC007AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 218470475 | 16.00 | 8.10 | 19700 | 2.13 | EPA 4621453 → |
5TXCC007AS3+TSTAT+ furnace: A801X100CM5SDAHRI reference: 218470474 | 16.00 | 8.10 | 19500 | 2.17 | EPA 4621454 → |
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 218470469 | 16.00 | 8.10 | 19300 | 2.19 | EPA 4621459 → |
5PX*DD10AS3+TSTAT+P0V0D000M50SDAHRI reference: 218470466 | 16.00 | 8.10 | 19200 | 2.21 | EPA 4621462 → |
5PX*DD10AS3+TSTAT+ furnace: A801X120DM5SDAHRI reference: 218470465 | 16.00 | 8.10 | 19400 | 2.19 | EPA 4621463 → |
5PX*DD10AS3+TSTAT+ furnace: A952V120DD5SBAHRI reference: 218470463 | 16.00 | 8.10 | 19100 | 2.23 | EPA 4621465 → |
5PX*D010AS3+TSTAT+P0V0D000M50SDAHRI reference: 218470460 | 16.00 | 8.10 | 19200 | 2.24 | EPA 4621467 → |