43 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,400–29,400BTU/h

Each efficiency range summarizes published EPA records for N5HP5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 43 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1643 / 43
EER2 · BTU/Wh11.7–1243 / 43
HSPF2 · BTU/Wh7.8–8.143 / 43
Cooling capacity · BTU/h27,400–29,40043 / 43
Heating capacity at 47°F / 8.3°C · BTU/h24,200–25,80043 / 43
Heating capacity at 17°F / −8.3°C · BTU/h17,100–17,60043 / 43
Heating capacity at 5°F / −15°C · BTU/h13,300–13,70043 / 43
COP at 5°F / −15°C2.13–2.2643 / 43
Equipment / loop typeHP - Split System43 / 43
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)43 / 43
Compressor stagingSingle stage43 / 43
Connected capabilityNo43 / 43

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
A5AHV006A1D3+TDR+TSTATAHRI reference: 21847027216.008.10133002.26EPA 4621585
A5AHV005A1D3+TDR+TSTATAHRI reference: 21847027116.008.10134002.24EPA 4621586
5TXCC009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21847026016.008.10136002.18EPA 4621591
5TXCC007AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21847025716.008.10136002.16EPA 4621593
5PX*D010AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 21847022116.008.10133002.22EPA 4621602
5PX*C009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21847021516.008.10136002.18EPA 4621603
5PX*C007AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21847021216.008.10136002.16EPA 4621605
5PX*BD06AS3+TSTAT+ furnace: A952V040BD3SBAHRI reference: 21847020516.008.10135002.16EPA 4621610
5PX*BD06AS3+TSTAT+ furnace: A951X060BD3SAAHRI reference: 21847020416.008.10135002.16EPA 4621611
5PX*BD06AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21847020316.008.10133002.18EPA 4621612
5PX*BD06AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21847020216.008.10134002.19EPA 4621613
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21847020116.008.10133002.20EPA 4621614
5PX*BD06AS3+TSTAT+ furnace: A952V060BD3SBAHRI reference: 21847019716.008.00133002.16EPA 4621617
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21847072915.508.10135002.20EPA 4621392
5TXCC009AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 21847069715.508.00134002.20EPA 4621396
5TXCB006AS3+TSTAT+ furnace: A951X040BU3SAAHRI reference: 21847069415.507.80135002.17EPA 4621397
5TXCC009AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21847026115.508.10135002.20EPA 4621590
5TXCC007AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 21847025815.508.10135002.19EPA 4621592
5TXCC007AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21847025615.507.80135002.18EPA 4621594
5TXCB006AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 21847024615.508.00135002.18EPA 4621595

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →