N5HP5030A1
Bronze 15
43 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5HP5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 43 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 43 / 43 |
| EER2 · BTU/Wh | 11.7–12 | 43 / 43 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 43 / 43 |
| Cooling capacity · BTU/h | 27,400–29,400 | 43 / 43 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,200–25,800 | 43 / 43 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,100–17,600 | 43 / 43 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,300–13,700 | 43 / 43 |
| COP at 5°F / −15°C | 2.13–2.26 | 43 / 43 |
| Equipment / loop type | HP - Split System | 43 / 43 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 43 / 43 |
| Compressor staging | Single stage | 43 / 43 |
| Connected capability | No | 43 / 43 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
A5AHV006A1D3+TDR+TSTATAHRI reference: 218470272 | 16.00 | 8.10 | 13300 | 2.26 | EPA 4621585 → |
A5AHV005A1D3+TDR+TSTATAHRI reference: 218470271 | 16.00 | 8.10 | 13400 | 2.24 | EPA 4621586 → |
5TXCC009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 218470260 | 16.00 | 8.10 | 13600 | 2.18 | EPA 4621591 → |
5TXCC007AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 218470257 | 16.00 | 8.10 | 13600 | 2.16 | EPA 4621593 → |
5PX*D010AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 218470221 | 16.00 | 8.10 | 13300 | 2.22 | EPA 4621602 → |
5PX*C009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 218470215 | 16.00 | 8.10 | 13600 | 2.18 | EPA 4621603 → |
5PX*C007AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 218470212 | 16.00 | 8.10 | 13600 | 2.16 | EPA 4621605 → |
5PX*BD06AS3+TSTAT+ furnace: A952V040BD3SBAHRI reference: 218470205 | 16.00 | 8.10 | 13500 | 2.16 | EPA 4621610 → |
5PX*BD06AS3+TSTAT+ furnace: A951X060BD3SAAHRI reference: 218470204 | 16.00 | 8.10 | 13500 | 2.16 | EPA 4621611 → |
5PX*BD06AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 218470203 | 16.00 | 8.10 | 13300 | 2.18 | EPA 4621612 → |
5PX*BD06AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 218470202 | 16.00 | 8.10 | 13400 | 2.19 | EPA 4621613 → |
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 218470201 | 16.00 | 8.10 | 13300 | 2.20 | EPA 4621614 → |
5PX*BD06AS3+TSTAT+ furnace: A952V060BD3SBAHRI reference: 218470197 | 16.00 | 8.00 | 13300 | 2.16 | EPA 4621617 → |
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 218470729 | 15.50 | 8.10 | 13500 | 2.20 | EPA 4621392 → |
5TXCC009AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 218470697 | 15.50 | 8.00 | 13400 | 2.20 | EPA 4621396 → |
5TXCB006AS3+TSTAT+ furnace: A951X040BU3SAAHRI reference: 218470694 | 15.50 | 7.80 | 13500 | 2.17 | EPA 4621397 → |
5TXCC009AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 218470261 | 15.50 | 8.10 | 13500 | 2.20 | EPA 4621590 → |
5TXCC007AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 218470258 | 15.50 | 8.10 | 13500 | 2.19 | EPA 4621592 → |
5TXCC007AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 218470256 | 15.50 | 7.80 | 13500 | 2.18 | EPA 4621594 → |
5TXCB006AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 218470246 | 15.50 | 8.00 | 13500 | 2.18 | EPA 4621595 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →