American Standard / AIR-SOURCE HEAT PUMP

N5HP5024A1

Bronze 15 · source records, page 3

81 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,600–24,200BTU/h

Each efficiency range summarizes published EPA records for N5HP5024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 81 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1681 / 81
EER2 · BTU/Wh11.7–1281 / 81
HSPF2 · BTU/Wh7.8–8.181 / 81
Cooling capacity · BTU/h22,600–24,20081 / 81
Heating capacity at 47°F / 8.3°C · BTU/h20,800–22,40081 / 81
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,20081 / 81
Heating capacity at 5°F / −15°C · BTU/h10,900–11,60081 / 81
COP at 5°F / −15°C2.02–2.2881 / 81
Equipment / loop typeHP - Split System81 / 81
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)81 / 81
Compressor stagingSingle stage81 / 81
Connected capabilityNo81 / 81

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: A951X040BU3SAAHRI reference: 21873667316.008.00112002.20EPA 4704920 →
5PX*B006AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21873667116.008.10115002.19EPA 4704922 →
5PX*B006AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21873666916.008.10114002.19EPA 4704924 →
5TXCB006AS3+TSTAT+ furnace: A801X060AM3SDAHRI reference: 21847067515.508.00113002.17EPA 4621398 →
5PX*B006AS3+TSTAT+ furnace: A801X060AM3SDAHRI reference: 21847066715.508.00113002.17EPA 4621400 →
A5AHV003A1B3+TDR+TSTATAHRI reference: 21873690515.508.10115002.15EPA 4704800 →
A5AHV002A1B3+TDR+TSTATAHRI reference: 21873690315.508.10115002.17EPA 4704802 →
5TXCC009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21873689315.508.00109002.19EPA 4704808 →
5TXCC007AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21873689115.508.00110002.19EPA 4704810 →
5TXCB004AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21873684515.507.80114002.15EPA 4704844 →
5TXCB004AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21873684315.508.00114002.13EPA 4704846 →
5TXCB004AS3+TSTAT+ furnace: A951X060BU4SAAHRI reference: 21873683915.508.00115002.13EPA 4704848 →
5TXCB004AS3+TSTAT+ furnace: A952V040BU3SBAHRI reference: 21873683515.508.00114002.15EPA 4704852 →
5TXCB004AS3+TSTAT+P0V0B000M40SDAHRI reference: 21873682515.508.00112002.18EPA 4704860 →
5TXCB003AS3+TSTAT+ furnace: A951X080BU4SAAHRI reference: 21873680315.507.80116002.02EPA 4704862 →
5TXCB003AS3+TSTAT+P0V0B000M40SDAHRI reference: 21873679315.507.80113002.05EPA 4704864 →
5PX*C009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21873677715.508.00109002.19EPA 4704866 →
5PX*C007AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21873677515.508.00110002.19EPA 4704868 →
5PX*B004AS3+TSTAT+P0V0B000M40SDAHRI reference: 21873665515.508.00112002.18EPA 4704932 →
5PX*B004AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21873664715.507.80114002.15EPA 4704936 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →