| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.5–18.1 | 113 / 113 |
| EER2 · BTU/Wh | 9.5–10.5 | 113 / 113 |
| HSPF2 · BTU/Wh | 8.5 | 113 / 113 |
| Cooling capacity · BTU/h | 50,000–55,000 | 113 / 113 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 52,500–56,000 | 113 / 113 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 47,000–50,000 | 113 / 113 |
| Heating capacity at 5°F / −15°C · BTU/h | 38,000–41,000 | 113 / 113 |
| COP at 5°F / −15°C | 1.9–2.1 | 113 / 113 |
| Equipment / loop type | HP - Split System | 113 / 113 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 113 / 113 |
| Compressor staging | Continuously variable | 113 / 113 |
| Connected capability | No | 113 / 113 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCD010AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 215864764 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715766 → |
5TXCD010AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 215864766 | 18.10 | 8.50 | 40000 | 2.00 | EPA 3715768 → |
5TXCD010AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 215864768 | 18.10 | 8.50 | 40000 | 2.00 | EPA 3715770 → |
5TXCD010AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 215864770 | 18.10 | 8.50 | 40000 | 2.00 | EPA 3715772 → |
5TXCD010AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 215864772 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715774 → |
5TXCD010AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 215864774 | 18.10 | 8.50 | 40000 | 2.00 | EPA 3715776 → |
5TXCD010AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 215864776 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715778 → |
5TXCD010AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 215864778 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715780 → |
5TXCD010AS3+ furnace: L8V1C100U5VSB+LRPCold climate designationAHRI reference: 215864780 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715782 → |
5PX*C009AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 215864998 | 18.10 | 8.50 | 40000 | 2.00 | EPA 3715931 → |
5PX*C009AS3+ furnace: L8V1C100U5VSB+LRPCold climate designationAHRI reference: 215865000 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715933 → |
5PX*C009AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 215865002 | 18.10 | 8.50 | 40000 | 2.00 | EPA 3715935 → |
5PX*C009AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 215865004 | 18.10 | 8.50 | 40000 | 2.00 | EPA 3715937 → |
5PX*C009AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 215865006 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715939 → |
5PX*CD09AS3+ furnace: S9V2C100D5PSC+LRPCold climate designationAHRI reference: 215865008 | 18.10 | 8.50 | 39500 | 1.90 | EPA 3715940 → |
5PX*D010AS3+ furnace: L8V1C100U5VSB+LRPCold climate designationAHRI reference: 215865010 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715943 → |
5PX*D010AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 215865012 | 18.10 | 8.50 | 40000 | 2.00 | EPA 3715945 → |
5PX*D010AS3+ furnace: S9V2D120U5VSB+LRPCold climate designationAHRI reference: 215865014 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715947 → |
5PX*D010AS3+ furnace: S9V2D120U5PSC+LRPCold climate designationAHRI reference: 215865016 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715949 → |
5PX*D010AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 215865018 | 18.10 | 8.50 | 39500 | 2.00 | EPA 3715951 → |