American Standard / AIR-SOURCE HEAT PUMP

5A6V8X48A1

PLATINUM 18 · source records, page 7

144 published source records · source checked Sep 21, 2026

SEER2 range18.1BTU/Wh
HSPF2 range8.5BTU/Wh
Cooling capacity43,500–47,500BTU/h

Each efficiency range summarizes published EPA records for 5A6V8X48A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18.1144 / 144
EER2 · BTU/Wh10–11.2144 / 144
HSPF2 · BTU/Wh8.5144 / 144
Cooling capacity · BTU/h43,500–47,500144 / 144
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000144 / 144
Heating capacity at 17°F / −8.3°C · BTU/h41,500–43,000144 / 144
Heating capacity at 5°F / −15°C · BTU/h34,000–38,500144 / 144
COP at 5°F / −15°C2.09–2.2144 / 144
Equipment / loop typeHP - Split System144 / 144
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)144 / 144
Compressor stagingContinuously variable144 / 144
Connected capabilityNo144 / 144

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*DD10AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 21586510018.108.50344002.20EPA 3716022
5PX*DD10AS3+P0V0D000M50SD+LRPCold climate designationAHRI reference: 21586510218.108.50342002.20EPA 3716023
5TXCC007AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 21586510418.108.50350002.20EPA 3716025
5TXCC009AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 21586510618.108.50346002.20EPA 3716027
5TXCD008AS3+P0V0D000M50SD+LRPCold climate designationAHRI reference: 21586511018.108.50348002.20EPA 3716029
5TXCD008AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 21586510818.108.50348002.20EPA 3716030
5TXCD010AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 21586511218.108.50344002.20EPA 3716032
5TXCD010AS3+P0V0D000M50SD+LRPCold climate designationAHRI reference: 21586511418.108.50342002.20EPA 3716035
5TEMCD05AV41+TDRCold climate designationAHRI reference: 21586504218.108.50340002.20EPA 3737793
5TEMCD07AV51+TDRCold climate designationAHRI reference: 21586504418.108.50344002.20EPA 3737795
5PX*B006AS3+ furnace: S9V2B060U4VSB+LRPCold climate designationAHRI reference: 21586911518.108.50354002.10EPA 3799647
5PX*C007AS3+ furnace: S9V2C080U5VSB+LRPCold climate designationAHRI reference: 21586911718.108.50354002.10EPA 3799682
5PX*C007AS3+ furnace: S9V2C100U5VSB+LRPCold climate designationAHRI reference: 21586911918.108.50354002.10EPA 3799683
5TXCB006AS3+ furnace: S9V2B060U4VSB+LRPCold climate designationAHRI reference: 21586912118.108.50354002.10EPA 3799685
5TXCC007AS3+ furnace: S9V2C100U5VSB+LRPCold climate designationAHRI reference: 21586912318.108.50352002.10EPA 3799687
5TAMXD05AV41Cold climate designationAHRI reference: 21605701118.108.50346002.10EPA 3845978
5TAMXD06AV41Cold climate designationAHRI reference: 21605701318.108.50348002.10EPA 3845980
5TAMXD07AV51Cold climate designationAHRI reference: 21605701518.108.50344002.10EPA 3845982
5TXCC009AS3+ furnace: S9V2C100U5VSB+LRPCold climate designationAHRI reference: 21808266518.108.50346002.14EPA 4569867
5TXCC009AS3+ furnace: S9V2C100U5VSB+VCKITCold climate designationAHRI reference: 21808266318.108.50348002.15EPA 4569869

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →