5A6V8X48A1
PLATINUM 18 · source records, page 2
144 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5A6V8X48A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18.1 | 144 / 144 |
| EER2 · BTU/Wh | 10–11.2 | 144 / 144 |
| HSPF2 · BTU/Wh | 8.5 | 144 / 144 |
| Cooling capacity · BTU/h | 43,500–47,500 | 144 / 144 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,500–47,000 | 144 / 144 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,500–43,000 | 144 / 144 |
| Heating capacity at 5°F / −15°C · BTU/h | 34,000–38,500 | 144 / 144 |
| COP at 5°F / −15°C | 2.09–2.2 | 144 / 144 |
| Equipment / loop type | HP - Split System | 144 / 144 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 144 / 144 |
| Compressor staging | Continuously variable | 144 / 144 |
| Connected capability | No | 144 / 144 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*DD10AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 215864916 | 18.10 | 8.50 | 34800 | 2.10 | EPA 3715400 → |
5PX*DD10AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 215864918 | 18.10 | 8.50 | 34800 | 2.10 | EPA 3715402 → |
5PX*DD10AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 215864920 | 18.10 | 8.50 | 34800 | 2.10 | EPA 3715403 → |
5TXCC007AS3+ furnace: L8V1C100U5VSB+LRPCold climate designationAHRI reference: 215864922 | 18.10 | 8.50 | 35200 | 2.10 | EPA 3715405 → |
5TXCC007AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 215864924 | 18.10 | 8.50 | 35200 | 2.10 | EPA 3715407 → |
5TXCC007AS3+ furnace: S9V2C100U4VSB+LRPCold climate designationAHRI reference: 215864926 | 18.10 | 8.50 | 35200 | 2.10 | EPA 3715410 → |
5TXCC007AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 215864928 | 18.10 | 8.50 | 35200 | 2.10 | EPA 3715412 → |
5TXCC007AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 215864930 | 18.10 | 8.50 | 35600 | 2.10 | EPA 3715414 → |
5TXCC007AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 215864932 | 18.10 | 8.50 | 35600 | 2.10 | EPA 3715416 → |
5TXCC007AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 215864934 | 18.10 | 8.50 | 35200 | 2.10 | EPA 3715418 → |
5TXCC007AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 215864936 | 18.10 | 8.50 | 35200 | 2.10 | EPA 3715420 → |
5TXCC007AS3+ furnace: *UHMC100CCV4+LRPCold climate designationAHRI reference: 215864938 | 18.10 | 8.50 | 35000 | 2.10 | EPA 3715422 → |
5TXCC009AS3+ furnace: S9V2C100U4VSB+LRPCold climate designationAHRI reference: 215864940 | 18.10 | 8.50 | 34800 | 2.10 | EPA 3715423 → |
5TXCC009AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 215864942 | 18.10 | 8.50 | 35000 | 2.10 | EPA 3715426 → |
5PX*C007AS3+ furnace: *UHMC100CCV4+LRPCold climate designationAHRI reference: 215864646 | 18.10 | 8.50 | 35000 | 2.10 | EPA 3715487 → |
5PX*C007AS3+ furnace: L8V1C100U5VSB+LRPCold climate designationAHRI reference: 215864648 | 18.10 | 8.50 | 35200 | 2.20 | EPA 3715489 → |
5PX*C007AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 215864650 | 18.10 | 8.50 | 35400 | 2.10 | EPA 3715491 → |
5PX*C007AS3+ furnace: S9V2C100U4VSB+LRPCold climate designationAHRI reference: 215864652 | 18.10 | 8.50 | 35400 | 2.10 | EPA 3715492 → |
5PX*C007AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 215864654 | 18.10 | 8.50 | 35400 | 2.10 | EPA 3715495 → |
5PX*C007AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 215864656 | 18.10 | 8.50 | 35400 | 2.10 | EPA 3715497 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →