Heating performance & equipment details
Ranges include the 201 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.1–18.1 | 201 / 201 |
| EER2 · BTU/Wh | 9.8–11 | 201 / 201 |
| HSPF2 · BTU/Wh | 8.5 | 201 / 201 |
| Cooling capacity · BTU/h | 31,400–33,600 | 201 / 201 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,200–34,600 | 201 / 201 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,400–32,200 | 201 / 201 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,800–26,000 | 201 / 201 |
| COP at 5°F / −15°C | 1.9–2.2 | 201 / 201 |
| Equipment / loop type | HP - Split System | 201 / 201 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 201 / 201 |
| Compressor staging | Continuously variable | 201 / 201 |
| Connected capability | No | 201 / 201 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*CD09AS3+ furnace: *DHMC100CCV4+LRPCold climate designationAHRI reference: 216571275 | 18.10 | 8.50 | 25200 | 2.10 | EPA 3848717 → |
5PX*CD09AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 216571277 | 18.10 | 8.50 | 25200 | 2.10 | EPA 3848720 → |
5PX*CD09AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216571279 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3848721 → |
5PX*CD09AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 216571281 | 18.10 | 8.50 | 25200 | 2.10 | EPA 3848724 → |
5PX*CD09AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216571283 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3848726 → |
5PX*D008AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 216571285 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3848728 → |
5PX*D008AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 216571287 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3848730 → |
5PX*D010AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 216571289 | 18.10 | 8.50 | 25200 | 2.10 | EPA 3848732 → |
5PX*B004AS3+P0V0B000M40SD+LRPCold climate designationAHRI reference: 216599664 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3956385 → |
5TXCB004AS3+P0V0B000M40SD+LRPCold climate designationAHRI reference: 216599666 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3956387 → |
5TXCB006AS3+P0V0B000M40SD+LRPCold climate designationAHRI reference: 216599668 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3956393 → |
5TXCC007AS3+ furnace: S9V2B060U4VSB+VCKITCold climate designationAHRI reference: 218036520 | 18.10 | 8.50 | 25600 | 2.12 | EPA 4569169 → |
5TXCC007AS3+ furnace: S9V2C080U5VSB+VCKITCold climate designationAHRI reference: 218036518 | 18.10 | 8.50 | 25800 | 2.14 | EPA 4569171 → |
5TXCC007AS3+ furnace: S9V2C100U5VSB+VCKITCold climate designationAHRI reference: 218036516 | 18.10 | 8.50 | 25600 | 2.14 | EPA 4569173 → |
5TXCC005AS3+ furnace: S9V2C100U5VSB+VCKITCold climate designationAHRI reference: 218036514 | 18.10 | 8.50 | 25400 | 2.08 | EPA 4569175 → |
5TXCC005AS3+ furnace: S9V2C100U4VSB+VCKITCold climate designationAHRI reference: 218036512 | 18.10 | 8.50 | 25400 | 2.08 | EPA 4569177 → |
5TXCB006AS3+ furnace: S9V2B040U3VSB+VCKITCold climate designationAHRI reference: 218036510 | 18.10 | 8.50 | 26000 | 2.11 | EPA 4569179 → |
5TXCB006AS3+ furnace: S9V2B060U4VSB+VCKITCold climate designationAHRI reference: 218036508 | 18.10 | 8.50 | 25800 | 2.13 | EPA 4569181 → |
5TXCB006AS3+ furnace: S9V2B060U3VSB+VCKITCold climate designationAHRI reference: 218036506 | 18.10 | 8.50 | 25800 | 2.13 | EPA 4569183 → |
5TXCB006AS3+ furnace: S9V2B080U4VSB+VCKITCold climate designationAHRI reference: 218036504 | 18.10 | 8.50 | 25800 | 2.11 | EPA 4569185 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.