5A6V0X36A1
PLATINUM 20
112 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5A6V0X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 112 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19.2–21 | 112 / 112 |
| EER2 · BTU/Wh | 12–13 | 112 / 112 |
| HSPF2 · BTU/Wh | 9.4–10.5 | 112 / 112 |
| Cooling capacity · BTU/h | 34,600–36,200 | 112 / 112 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,600–33,200 | 112 / 112 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,400–31,600 | 112 / 112 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–25,400 | 112 / 112 |
| COP at 5°F / −15°C | 2.1–2.24 | 112 / 112 |
| Equipment / loop type | HP - Split System | 112 / 112 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 112 / 112 |
| Compressor staging | Continuously variable | 112 / 112 |
| Connected capability | No | 112 / 112 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TAMXD06AV41Cold climate designationAHRI reference: 216440115 | 21.00 | 9.70 | 24800 | 2.10 | EPA 3846215 → |
5PX*D010AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 216453110 | 21.00 | 10.00 | 24600 | 2.20 | EPA 3846699 → |
5PX*D010AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 216453112 | 21.00 | 10.00 | 24600 | 2.20 | EPA 3846701 → |
5TXCD010AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 216453138 | 20.80 | 10.00 | 24600 | 2.20 | EPA 3846727 → |
5TXCD010AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 216453140 | 20.80 | 10.00 | 24600 | 2.20 | EPA 3846729 → |
5PX*C009AS3+ furnace: *UHMC100CCV4+LRPCold climate designationAHRI reference: 216570993 | 20.60 | 9.70 | 24400 | 2.20 | EPA 3848459 → |
5TXCC009AS3+ furnace: *UHMC100CCV4+LRPCold climate designationAHRI reference: 216571075 | 20.60 | 9.70 | 24400 | 2.20 | EPA 3848500 → |
5PX*C009AS3+ furnace: S9V2B060D3VSB+LRPCold climate designationAHRI reference: 217179370 | 20.60 | 9.70 | 24600 | 2.10 | EPA 4010383 → |
5TXCC009AS3+ furnace: S9V2B060D3PSC+LRPCold climate designationAHRI reference: 217179430 | 20.60 | 9.50 | 24600 | 2.10 | EPA 4010453 → |
5TXCC009AS3+ furnace: S9V2B060D3VSB+LRPCold climate designationAHRI reference: 217179432 | 20.60 | 9.50 | 24600 | 2.10 | EPA 4010454 → |
5TXCC009AS3+ furnace: S9V2C080U5VSB+VCKITCold climate designationAHRI reference: 218036360 | 20.60 | 9.40 | 23800 | 2.10 | EPA 4569303 → |
5TXCC009AS3+ furnace: S9V2C100U4VSB+VCKITCold climate designationAHRI reference: 218036358 | 20.60 | 9.40 | 23800 | 2.10 | EPA 4569305 → |
5TXCC009AS3+ furnace: S9V2C100U5VSB+VCKITCold climate designationAHRI reference: 218036356 | 20.60 | 9.40 | 23800 | 2.10 | EPA 4569307 → |
5PX*CD09AS3+ furnace: S9V2B060D3VSB+VCKITCold climate designationAHRI reference: 218036348 | 20.60 | 9.70 | 24400 | 2.10 | EPA 4569315 → |
5PX*C009AS3+ furnace: S9V2C100U5VSB+VCKITCold climate designationAHRI reference: 218036342 | 20.60 | 9.40 | 23800 | 2.10 | EPA 4569321 → |
5PX*C009AS3+ furnace: S9V2C100U4VSB+VCKITCold climate designationAHRI reference: 218036340 | 20.60 | 9.40 | 23800 | 2.10 | EPA 4569323 → |
5PX*C009AS3+ furnace: S9V2C080U5VSB+VCKITCold climate designationAHRI reference: 218036338 | 20.60 | 9.40 | 23800 | 2.10 | EPA 4569325 → |
5TAMXD05AV41Cold climate designationAHRI reference: 216440113 | 20.40 | 10.00 | 24600 | 2.10 | EPA 3846213 → |
5PX*DD10AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 216453114 | 20.40 | 9.70 | 24600 | 2.10 | EPA 3846703 → |
5PX*DD10AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 216453116 | 20.40 | 9.70 | 24600 | 2.10 | EPA 3846705 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →