American Standard / AIR-SOURCE HEAT PUMP

5A6H7048A1

GOLD 17 · source records, page 9

231 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.5–9.4BTU/Wh
Cooling capacity43,000–44,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H7048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1231 / 231
EER2 · BTU/Wh11.2–12.5231 / 231
HSPF2 · BTU/Wh8.5–9.4231 / 231
Cooling capacity · BTU/h43,000–44,500231 / 231
Heating capacity at 47°F / 8.3°C · BTU/h43,500–46,000231 / 231
Heating capacity at 17°F / −8.3°C · BTU/h28,800–41,000231 / 231
Heating capacity at 5°F / −15°C · BTU/h31,800–33,800231 / 231
COP at 5°F / −15°C2.1–2.26231 / 231
Equipment / loop typeHP - Split System231 / 231
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)231 / 231
Compressor stagingTwo-stage231 / 231
Connected capabilityNo231 / 231

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D010AS3+ furnace: S8V2C080M5PDBAHRI reference: 21676652916.508.70320002.20EPA 4585736
5PX*D008AS3+ furnace: S9X2C080U5PSBCold climate designationAHRI reference: 21676648716.508.70332002.20EPA 4585742
5PX*C009AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 21676645916.508.70322002.20EPA 4585754
5PX*C009AS3+ furnace: S8V2C100M5PDBAHRI reference: 21676645716.508.70320002.20EPA 4585756
5TXCD008AS3+ furnace: S8X1C100M5PSCCold climate designationAHRI reference: 21833193916.508.70330002.20EPA 4586019
5TXCD008AS3+P0V0C000M50SDAHRI reference: 21833193716.509.00324002.20EPA 4586021
5TXCD010AS3+ furnace: S8V2C080M5PDBAHRI reference: 21676660916.508.70320002.20EPA 4586047
5TXCD008AS3+ furnace: S8V2D120M5PDBAHRI reference: 21676658916.509.00324002.20EPA 4586049
5TXCC009AS3+ furnace: S8V2C100M5PDBAHRI reference: 21676657716.508.70320002.20EPA 4586050
5TXCC009AS3+ furnace: S9X2C080U5PSBAHRI reference: 21676656316.508.70320002.20EPA 4586051
5PX*D008AS3+ furnace: S8V2D120M5PDBAHRI reference: 21676647916.509.00324002.20EPA 4586056
5PX*CD09AS3+ furnace: S8V2C080M5PDBAHRI reference: 21676647116.508.50320002.10EPA 4586058
5PX*C009AS3+ furnace: S9X2C080U5PSBAHRI reference: 21676645516.508.70320002.20EPA 4586059
5PX*C009AS3Cold climate designationAHRI reference: 21676392816.009.00326002.10EPA 3979826
5PX*D010AS3Cold climate designationAHRI reference: 21676397416.009.00328002.10EPA 3979871
5TXCC009AS3Cold climate designationAHRI reference: 21676400216.009.00326002.10EPA 3980150
5PX*C009AS3+ furnace: S9V2C100U5VSBCold climate designationAHRI reference: 21676644316.008.70324002.20EPA 3983206
5PX*CD07AS3+P0V0C000M50SDAHRI reference: 21676646116.008.70330002.16EPA 3983256
5PX*CD09AS3+ furnace: S9X1C100D5PSBCold climate designationAHRI reference: 21676646316.008.50324002.10EPA 3983258
5PX*CD09AS3+ furnace: S8V2C100M5PCBAHRI reference: 21676647316.008.70322002.17EPA 3983264