5A6H7048A1
GOLD 17 · source records, page 2
231 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5A6H7048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.1 | 231 / 231 |
| EER2 · BTU/Wh | 11.2–12.5 | 231 / 231 |
| HSPF2 · BTU/Wh | 8.5–9.4 | 231 / 231 |
| Cooling capacity · BTU/h | 43,000–44,500 | 231 / 231 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–46,000 | 231 / 231 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,800–41,000 | 231 / 231 |
| Heating capacity at 5°F / −15°C · BTU/h | 31,800–33,800 | 231 / 231 |
| COP at 5°F / −15°C | 2.1–2.26 | 231 / 231 |
| Equipment / loop type | HP - Split System | 231 / 231 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 231 / 231 |
| Compressor staging | Two-stage | 231 / 231 |
| Connected capability | No | 231 / 231 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*D010AS3+ furnace: S9V2C080U5PSCAHRI reference: 216763970 | 17.10 | 9.00 | 31800 | 2.20 | EPA 3979872 → |
5PX*D010AS3+ furnace: L8V1C100U5VSBAHRI reference: 216763978 | 17.10 | 9.00 | 32000 | 2.20 | EPA 3980128 → |
5PX*D010AS3+ furnace: S8X1D120M5PSCAHRI reference: 216763968 | 17.10 | 9.00 | 32400 | 2.20 | EPA 3980130 → |
5PX*D010AS3+ furnace: S8X1C080M5PSCAHRI reference: 216763972 | 17.10 | 9.00 | 32200 | 2.20 | EPA 3980131 → |
5TAM5D06AC41AHRI reference: 216763986 | 17.10 | 8.70 | 31800 | 2.10 | EPA 3980132 → |
5PX*DD10AS3+ furnace: S8X1D120M5PSCAHRI reference: 216763982 | 17.10 | 9.00 | 32600 | 2.20 | EPA 3980133 → |
5PX*DD10AS3+ furnace: S9V2D120D5PSCAHRI reference: 216763984 | 17.10 | 9.00 | 32400 | 2.20 | EPA 3980137 → |
5PX*DD10AS3+ furnace: S8X1C080M5PSCAHRI reference: 216763980 | 17.10 | 9.00 | 32600 | 2.10 | EPA 3980138 → |
5TAMXD06AV41AHRI reference: 216763990 | 17.10 | 9.00 | 32400 | 2.10 | EPA 3980142 → |
5TAM5D07AC51AHRI reference: 216763988 | 17.10 | 9.40 | 32400 | 2.20 | EPA 3980143 → |
5TAMXD07AV51Cold climate designationAHRI reference: 216763992 | 17.10 | 9.00 | 32000 | 2.10 | EPA 3980146 → |
5TEM6D06AV41+TDRAHRI reference: 216763994 | 17.10 | 9.00 | 31800 | 2.20 | EPA 3980147 → |
5TEMCD07AV51+TDRAHRI reference: 216764000 | 17.10 | 9.00 | 31800 | 2.20 | EPA 3980154 → |
5TEM6D07AV51+TDRAHRI reference: 216763996 | 17.10 | 9.00 | 31800 | 2.20 | EPA 3980155 → |
5TEMCD06AV41+TDRAHRI reference: 216763998 | 17.10 | 9.00 | 31800 | 2.20 | EPA 3980156 → |
5TXCD010AS3+ furnace: L9X1C100U5VSACold climate designationAHRI reference: 216764010 | 17.10 | 8.70 | 32600 | 2.10 | EPA 3980158 → |
5TXCD010AS3+ furnace: S8X1C080M5PSCAHRI reference: 216764012 | 17.10 | 9.00 | 32200 | 2.20 | EPA 3980159 → |
5TXCC009AS3+ furnace: *UHMC100CCV4AHRI reference: 216764004 | 17.10 | 9.00 | 32200 | 2.20 | EPA 3980161 → |
5TXCD008AS3+ furnace: *UHMC100CCV4Cold climate designationAHRI reference: 216764006 | 17.10 | 9.00 | 32800 | 2.20 | EPA 3980163 → |
5TXCD010AS3+ furnace: S8X1C100M5PSCAHRI reference: 216764014 | 17.10 | 9.00 | 32200 | 2.20 | EPA 3980165 → |