American Standard / AIR-SOURCE HEAT PUMP

5A6H7024A1

GOLD 17 · source records, page 10

245 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.1–11BTU/Wh
Cooling capacity21,000–24,000BTU/h

Each efficiency range summarizes published EPA records for 5A6H7024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 245 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1245 / 245
EER2 · BTU/Wh11.5–12.5245 / 245
HSPF2 · BTU/Wh8.1–11245 / 245
Cooling capacity · BTU/h21,000–24,000245 / 245
Heating capacity at 47°F / 8.3°C · BTU/h20,600–22,600245 / 245
Heating capacity at 17°F / −8.3°C · BTU/h14,800–15,800245 / 245
Heating capacity at 5°F / −15°C · BTU/h16,700–17,700245 / 245
COP at 5°F / −15°C1.8–2.1245 / 245
Equipment / loop typeHP - Split System245 / 245
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)245 / 245
Compressor stagingTwo-stage245 / 245
Connected capabilityNo245 / 245

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*BD04AS3+ furnace: S8V2B080M4PDBAHRI reference: 21676587917.108.10171001.80EPA 4585981
5PX*BD04AS3+ furnace: S9X2B060D3PSBAHRI reference: 21676587117.108.10172001.80EPA 4585983
5PX*B006AS3+ furnace: S9X2B060U4PSBCold climate designationAHRI reference: 21676584117.109.00174002.00EPA 4585989
5PX*B006AS3+ furnace: S8V2B080M4PDBCold climate designationAHRI reference: 21676583717.109.00174002.00EPA 4585991
5PX*B006AS3+ furnace: S8V2B060M4PDBCold climate designationAHRI reference: 21676583517.109.00175002.00EPA 4585993
5PX*B006AS3+ furnace: S8V2A040M3PDBCold climate designationAHRI reference: 21676583317.109.00175002.00EPA 4585995
5PX*B004AS3+ furnace: S9X2B040U3PSBCold climate designationAHRI reference: 21676580717.108.70172002.00EPA 4586002
5PX*B004AS3+ furnace: S8V2A040M3PDBCold climate designationAHRI reference: 21676580517.108.70173002.00EPA 4586004
5PX*B004AS3+ furnace: S8V2B080M4PDBCold climate designationAHRI reference: 21676580317.108.70172002.00EPA 4586006
5PX*B004AS3+ furnace: S8V2B060M4PDBCold climate designationAHRI reference: 21676580117.108.70173002.00EPA 4586008
5PX*BD04AS3+ furnace: S8V2A040M3PDBAHRI reference: 21676588317.108.10172001.80EPA 4586063
5TXCB004AS3+ furnace: L9X1B070U4VSACold climate designationAHRI reference: 21676350317.008.70170001.90EPA 3979648
5PX*B004AS3+ furnace: L9X1B070U4VSACold climate designationAHRI reference: 21676334517.008.70170001.90EPA 3979886
5PX*BD06AS3+ furnace: S9X1B080D4PSBCold climate designationAHRI reference: 21676589717.008.50173001.90EPA 3983013
5PX*BD06AS3+ furnace: S9X2B080D4PSBCold climate designationAHRI reference: 21676590117.008.50173001.90EPA 4585966
5TXCB004AS3+ furnace: S9V2B080D4VSBCold climate designationAHRI reference: 21676351516.508.70169001.90EPA 3979653
5TXCB004AS3+ furnace: S9V2B080D4PSCCold climate designationAHRI reference: 21676351716.508.70169001.90EPA 3979658
5TXCB004AS3+ furnace: S9V2B040D3PSCCold climate designationAHRI reference: 21676352316.508.70169001.90EPA 3979660
5PX*B006AS3+ furnace: *DHMB060CCV3Cold climate designationAHRI reference: 21676340116.509.00171002.00EPA 3979685
5PX*B006AS3+ furnace: *DHMB080CCV3Cold climate designationAHRI reference: 21676340316.509.00172002.00EPA 3979686