5A6H6048A1
Silver 16
127 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5A6H6048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 127 / 127 |
| EER2 · BTU/Wh | 11.5–12 | 127 / 127 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 127 / 127 |
| Cooling capacity · BTU/h | 43,000–46,500 | 127 / 127 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 41,500–43,500 | 127 / 127 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,200–29,200 | 127 / 127 |
| Heating capacity at 5°F / −15°C · BTU/h | 21,800–22,600 | 127 / 127 |
| COP at 5°F / −15°C | 2.1–2.3 | 127 / 127 |
| Equipment / loop type | HP - Split System | 127 / 127 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 127 / 127 |
| Compressor staging | Single stage | 127 / 127 |
| Connected capability | No | 127 / 127 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 218109199 | 16.00 | 8.10 | 22000 | 2.20 | EPA 4574017 → |
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 218109197 | 16.00 | 8.10 | 22000 | 2.20 | EPA 4574019 → |
5TXCD010AS3+TSTAT+P0V0D000M50SDAHRI reference: 218109187 | 16.00 | 8.10 | 21800 | 2.24 | EPA 4574029 → |
5TXCD010AS3+TSTAT+P0V0C000M50SDAHRI reference: 218109185 | 16.00 | 7.80 | 21800 | 2.23 | EPA 4574031 → |
5TXCD010AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 218109183 | 16.00 | 7.80 | 22000 | 2.20 | EPA 4574033 → |
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 218109169 | 16.00 | 8.10 | 22200 | 2.19 | EPA 4574047 → |
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 218109167 | 16.00 | 8.10 | 22200 | 2.19 | EPA 4574049 → |
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 218109159 | 16.00 | 8.10 | 22200 | 2.19 | EPA 4574055 → |
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 218109157 | 16.00 | 8.10 | 22200 | 2.19 | EPA 4574057 → |
5TXCD008AS3+TSTAT+P0V0D000M50SDAHRI reference: 218109121 | 16.00 | 8.10 | 22000 | 2.17 | EPA 4574061 → |
5TXCD008AS3+TSTAT+P0V0C000M50SDAHRI reference: 218109119 | 16.00 | 8.00 | 22000 | 2.15 | EPA 4574063 → |
5TXCC009AS3+TSTAT+P0V0C000M50SDAHRI reference: 218109115 | 16.00 | 8.10 | 21800 | 2.22 | EPA 4574065 → |
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 218109093 | 16.00 | 8.10 | 22200 | 2.18 | EPA 4574075 → |
5TEMCD07AV51+TDR+TSTATAHRI reference: 218109019 | 16.00 | 8.10 | 21800 | 2.30 | EPA 4574079 → |
5TEMCD06AV41+TDR+TSTATAHRI reference: 218109017 | 16.00 | 8.50 | 22000 | 2.27 | EPA 4574081 → |
5TEM6D07AV51+TDR+TSTATAHRI reference: 218109013 | 16.00 | 8.10 | 21800 | 2.28 | EPA 4574085 → |
5TEM6D06AV41+TDR+TSTATAHRI reference: 218109011 | 16.00 | 8.10 | 21800 | 2.29 | EPA 4574087 → |
5PX*D010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 218108983 | 16.00 | 8.10 | 22000 | 2.20 | EPA 4574099 → |
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 218108979 | 16.00 | 8.10 | 22200 | 2.19 | EPA 4574103 → |
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 218108977 | 16.00 | 8.10 | 22200 | 2.19 | EPA 4574105 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →