American Standard / AIR-SOURCE HEAT PUMP

5A6H6042A1

Silver 16 · source records, page 8

248 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,600–41,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 248 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5248 / 248
EER2 · BTU/Wh11.7–12248 / 248
HSPF2 · BTU/Wh7.8–8.5248 / 248
Cooling capacity · BTU/h37,600–41,500248 / 248
Heating capacity at 47°F / 8.3°C · BTU/h37,600–40,500248 / 248
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,200248 / 248
Heating capacity at 5°F / −15°C · BTU/h18,700–19,900248 / 248
COP at 5°F / −15°C2.12–2.32248 / 248
Equipment / loop typeHP - Split System248 / 248
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)248 / 248
Compressor stagingSingle stage248 / 248
Connected capabilityNo248 / 248

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810832916.008.10194002.16EPA 4574515
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810832716.008.10193002.17EPA 4574517
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810832516.008.10194002.16EPA 4574519
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810832316.008.10193002.17EPA 4574521
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810832116.008.10193002.17EPA 4574523
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810831916.008.10193002.18EPA 4574525
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810824916.008.10191002.21EPA 4574555
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21815921816.008.10191002.22EPA 4576626
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839563716.008.10193002.17EPA 4599410
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21839563516.008.10193002.17EPA 4599412
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21839563316.008.10194002.16EPA 4599414
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21839563116.008.10194002.16EPA 4599416
5TEM6D05AV41+TDR+TSTATAHRI reference: 21839561916.008.10191002.22EPA 4599422
5PX*CD09AS3+TSTAT+ furnace: S9X1C100D5PSBAHRI reference: 21839560516.008.00196002.13EPA 4599434
5PX*CD09AS3+TSTAT+ furnace: S9X2C100D5PSBAHRI reference: 21839560316.008.00196002.13EPA 4599436
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839559916.008.10193002.17EPA 4599438
5TXCC007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810867515.208.10191002.20EPA 4574243
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21810866115.208.10192002.19EPA 4574257
5TXCC007AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21810865915.208.10194002.17EPA 4574259
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810865715.208.10192002.19EPA 4574261

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →