American Standard / AIR-SOURCE HEAT PUMP

5A6H6042A1

Silver 16

248 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,600–41,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 248 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5248 / 248
EER2 · BTU/Wh11.7–12248 / 248
HSPF2 · BTU/Wh7.8–8.5248 / 248
Cooling capacity · BTU/h37,600–41,500248 / 248
Heating capacity at 47°F / 8.3°C · BTU/h37,600–40,500248 / 248
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,200248 / 248
Heating capacity at 5°F / −15°C · BTU/h18,700–19,900248 / 248
COP at 5°F / −15°C2.12–2.32248 / 248
Equipment / loop typeHP - Split System248 / 248
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)248 / 248
Compressor stagingSingle stage248 / 248
Connected capabilityNo248 / 248

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+TSTAT+P0V0D000M50SDAHRI reference: 21810875116.508.10189002.28EPA 4574167 →
5TEMCD07AV51+TDR+TSTATAHRI reference: 21810855916.508.10187002.32EPA 4574333 →
5PX*D010AS3+TSTAT+P0V0D000M50SDAHRI reference: 21839561116.508.10191002.24EPA 4599430 →
5TEMCD07BV51+TDR+TSTATAHRI reference: 21878817216.508.10188002.32EPA 4704978 →
5TXCD010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21810876716.008.10192002.22EPA 4574151 →
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21810876516.008.10191002.24EPA 4574153 →
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21810876316.008.10191002.24EPA 4574155 →
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21810876116.008.10191002.24EPA 4574157 →
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21810875916.008.10191002.24EPA 4574159 →
5TXCD010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21810875716.008.10192002.22EPA 4574161 →
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21810875516.008.10191002.24EPA 4574163 →
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21810875316.008.10190002.24EPA 4574165 →
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21810874916.008.10191002.24EPA 4574169 →
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21810874716.008.10191002.24EPA 4574171 →
5TXCD008AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21810874516.008.10192002.19EPA 4574173 →
5TXCD008AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21810874316.008.10192002.19EPA 4574175 →
5TXCD008AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21810874116.008.10192002.19EPA 4574177 →
5TXCD008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21810873916.008.10193002.17EPA 4574179 →
5TXCD008AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21810873716.008.10192002.19EPA 4574181 →
5TXCD008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21810873516.008.10192002.20EPA 4574183 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →