American Standard / AIR-SOURCE HEAT PUMP

5A6H6036A1

Silver 16 · source records, page 5

371 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810814716.008.10172002.40EPA 4574653
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810814516.008.10172002.38EPA 4574655
5TXCC009AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810814316.008.10173002.38EPA 4574657
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810814116.008.10172002.38EPA 4574659
5TXCC009AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810813916.008.10173002.38EPA 4574661
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810813716.008.10172002.38EPA 4574663
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21810813516.008.10169002.39EPA 4574665
5TXCC009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810812916.008.10169002.43EPA 4574671
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21810812716.008.10170002.41EPA 4574673
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810812516.008.10171002.38EPA 4574675
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810811516.008.10173002.37EPA 4574685
5TXCC007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810811316.008.10170002.39EPA 4574687
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810811116.008.10173002.37EPA 4574689
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21810810916.008.10173002.37EPA 4574691
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21810809916.008.10173002.37EPA 4574701
5TXCC007AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810809716.008.10171002.42EPA 4574703
5TXCC007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21810809516.008.10171002.39EPA 4574705
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21810808916.008.10172002.38EPA 4574711
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810799516.008.10170002.40EPA 4574801
5TEMCD06AV41+TDR+TSTATAHRI reference: 21810790516.008.10170002.49EPA 4574849

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →