American Standard / AIR-SOURCE HEAT PUMP

5A6H6036A1

Silver 16 · source records, page 2

371 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810767716.008.10172002.38EPA 4573458
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810767316.008.10174002.38EPA 4573462
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810767116.008.10174002.37EPA 4573464
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810766916.008.10174002.38EPA 4573466
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810766716.008.10173002.38EPA 4573468
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810766516.008.10170002.39EPA 4573470
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21810765916.008.10170002.38EPA 4573476
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810765716.008.10171002.38EPA 4573478
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810765516.008.10174002.37EPA 4573480
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810765316.008.10173002.37EPA 4573482
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21810765116.008.10173002.37EPA 4573484
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21810764916.008.10170002.38EPA 4573486
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810764716.008.10174002.37EPA 4573488
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810764516.008.10174002.38EPA 4573490
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810764316.008.10174002.37EPA 4573492
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810764116.008.10174002.38EPA 4573494
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21810763916.008.10173002.38EPA 4573496
5PX*C007AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810763716.008.10171002.42EPA 4573498
5PX*C007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21810763516.008.10172002.39EPA 4573500
5PX*BD06AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21810758716.008.00173002.35EPA 4573544

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.