SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD09AS3+TSTAT+ furnace: S9X2C100D5PSBAHRI reference: 21810779715.208.10171002.34EPA 4574949 →
5PX*CD07AS3+TSTAT+ furnace: *DHMC100CCV4AHRI reference: 21810776915.208.10172002.32EPA 4574977 →
5PX*CD07AS3+TSTAT+ furnace: S9X2C100D5PSBAHRI reference: 21810776515.208.10175002.30EPA 4574981 →
5PX*CD07AS3+TSTAT+ furnace: S9X1C100D5PSBAHRI reference: 21810775715.208.10175002.30EPA 4574989 →
5PX*CD05AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810774315.208.00174002.23EPA 4574999 →
5PX*CD05AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810773915.208.00174002.23EPA 4575001 →
5PX*CD05AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810772715.208.00174002.23EPA 4575003 →
5PX*CD05AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810772315.208.00174002.23EPA 4575005 →
5TXCD008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21815921415.208.10170002.41EPA 4576630 →
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21815921215.208.10174002.36EPA 4576632 →
5PX*B006AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21815920815.208.00170002.36EPA 4576636 →
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21839557315.208.10174002.36EPA 4599450 →
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21839557115.208.10174002.36EPA 4599452 →
5TXCC005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21839556915.208.10172002.35EPA 4599454 →
5TXCB006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21839556715.208.10171002.37EPA 4599456 →
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21839556515.208.10174002.36EPA 4599458 →
5PX*DD10AS3+TSTAT+ furnace: *DHMD120CCV5AHRI reference: 21839551515.208.10171002.34EPA 4599460 →
5PX*CD07AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21839551115.208.10175002.31EPA 4599464 →
5PX*CD07AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21839550915.208.10176002.31EPA 4599466 →
5PX*CD07AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21839550715.208.10176002.31EPA 4599468 →

Sources and documentation