American Standard / AIR-SOURCE HEAT PUMP

5A6H5042A1

Silver 15 · source records, page 3

293 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,400–41,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 293 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17293 / 293
EER2 · BTU/Wh11.7–12293 / 293
HSPF2 · BTU/Wh7.8–8.5293 / 293
Cooling capacity · BTU/h37,400–41,500293 / 293
Heating capacity at 47°F / 8.3°C · BTU/h37,400–40,500293 / 293
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,400293 / 293
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000293 / 293
COP at 5°F / −15°C2–2.3293 / 293
Equipment / loop typeHP - Split System293 / 293
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)293 / 293
Compressor stagingSingle stage293 / 293
Connected capabilityNo293 / 293

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21407890416.008.10193002.10EPA 3424852
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21407890816.008.10192002.10EPA 3424856
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21407892216.008.10194002.10EPA 3424872
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21407891816.008.10194002.10EPA 3424873
5TXCC007AS3+TSTAT+P0V0C000M50SDAHRI reference: 21407892616.008.10191002.10EPA 3424874
5TXCC007AS3+TSTAT+P0V0C000M50SCAHRI reference: 21407892816.008.10191002.10EPA 3424876
5TXCC007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21407893216.008.10192002.10EPA 3424880
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21407894216.008.10191002.20EPA 3424890
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21407894416.008.10191002.20EPA 3424893
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21407894616.008.10191002.20EPA 3424894
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21407894816.008.10191002.20EPA 3424896
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21407895016.008.10191002.20EPA 3424898
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5PSBAHRI reference: 21407895216.008.10189002.20EPA 3424901
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSAAHRI reference: 21407895616.008.10189002.20EPA 3424906
5TXCD010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21407896016.008.10188002.20EPA 3424908
5TXCD010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21407896216.008.10188002.20EPA 3424910
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556880116.008.10196002.10EPA 3650100
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21557416916.008.10192002.10EPA 3650104
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21556889716.008.00193002.10EPA 3650182
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21556889916.008.10193002.10EPA 3650184

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →