American Standard / AIR-SOURCE HEAT PUMP

5A6H5036A1

Silver 15 · source records, page 6

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21556818716.008.10173002.30EPA 3650407
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556839316.008.10177002.20EPA 3650593
5TXCC005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556633516.008.10172002.30EPA 3650674
5TXCC009AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21556637916.008.10170002.30EPA 3650712
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21556638116.008.10172002.30EPA 3650714
5TXCC009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21556638516.008.10172002.30EPA 3650718
5TXCC009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21556638916.008.10172002.30EPA 3650722
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556639116.008.10171002.30EPA 3650724
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556639316.008.10171002.30EPA 3650726
5TXCC009AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21556639516.008.10173002.30EPA 3650728
5TXCC009AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21556639716.008.10173002.30EPA 3650730
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556639916.008.10174002.30EPA 3650732
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556640116.008.10174002.30EPA 3650735
5TXCC009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556640716.008.10172002.30EPA 3650774
5TXCC009AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21556640916.008.10174002.30EPA 3650775
5TXCC009AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21556641116.008.10174002.30EPA 3650778
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21556641316.008.10174002.30EPA 3650780
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21556641516.008.10174002.30EPA 3650782
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21556641716.008.10174002.30EPA 3650784
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21556641916.008.10174002.30EPA 3650786

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →