| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 30 / 30 |
| EER2 · BTU/Wh | 12 | 30 / 30 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 30 / 30 |
| Cooling capacity · BTU/h | 22,800–25,000 | 30 / 30 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,000–22,800 | 30 / 30 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,000–14,900 | 30 / 30 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,900–11,400 | 30 / 30 |
| COP at 5°F / −15°C | 2–2.2 | 30 / 30 |
| Equipment / loop type | HP - Split System | 30 / 30 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 30 / 30 |
| Compressor staging | Single stage | 30 / 30 |
| Connected capability | No | 30 / 30 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*B006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 215567327 | 16.50 | 8.00 | 11300 | 2.10 | EPA 3650116 → |
5TEMCD06AV41+TDR+TSTATAHRI reference: 215863921 | 16.50 | 7.80 | 11000 | 2.20 | EPA 3737593 → |
5TEMCD07AV51+TDR+TSTATAHRI reference: 215863923 | 16.50 | 7.80 | 11000 | 2.20 | EPA 3737595 → |
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDAAHRI reference: 214078336 | 16.00 | 7.80 | 11100 | 2.10 | EPA 3423674 → |
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 214078338 | 16.00 | 7.80 | 11300 | 2.10 | EPA 3423676 → |
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 214078340 | 16.00 | 7.80 | 11400 | 2.10 | EPA 3423678 → |
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 214078342 | 16.00 | 7.80 | 11300 | 2.10 | EPA 3423680 → |
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 214078344 | 16.00 | 7.80 | 11300 | 2.10 | EPA 3423682 → |
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 214078346 | 16.00 | 7.80 | 11400 | 2.10 | EPA 3423684 → |
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 214078348 | 16.00 | 7.80 | 11400 | 2.10 | EPA 3423686 → |
5TXCB006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 214078328 | 16.00 | 8.10 | 11400 | 2.10 | EPA 3424729 → |
5PX*B006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 215567323 | 16.00 | 8.00 | 11400 | 2.10 | EPA 3650112 → |
5PX*B006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 215567325 | 16.00 | 8.00 | 11400 | 2.10 | EPA 3650114 → |
5TEMCD04AV31+TDR+TSTATAHRI reference: 215863917 | 16.00 | 8.10 | 11100 | 2.20 | EPA 3737589 → |
5TEMCD05AV41+TDR+TSTATAHRI reference: 215863919 | 16.00 | 8.10 | 11100 | 2.20 | EPA 3737591 → |
5TAMXD05AV41+TSTATAHRI reference: 216056955 | 16.00 | 8.10 | 11100 | 2.10 | EPA 3845942 → |
5TEM4B04AC31+TDR+TSTATAHRI reference: 218154612 | 16.00 | 8.00 | 11300 | 2.10 | EPA 4575871 → |
5TXCB004AS3+TSTAT+ furnace: S8X1B040M2PTCAHRI reference: 214078318 | 15.20 | 7.80 | 11000 | 2.00 | EPA 3424718 → |
5TXCB004AS3+TSTAT+ furnace: S9V2B080U4VSAAHRI reference: 214078320 | 15.20 | 7.80 | 11300 | 2.10 | EPA 3424720 → |
5TXCB004AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 214078322 | 15.20 | 7.80 | 11100 | 2.10 | EPA 3424722 → |