American Standard / AIR-SOURCE HEAT PUMP

4A6V8X60A1

PLATINUM 18 · XV18I · source records, page 4

86 published source records · source checked Sep 21, 2026

SEER2 range18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–54,500BTU/h

Each efficiency range summarizes published EPA records for 4A6V8X60A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 86 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh1886 / 86
EER2 · BTU/Wh11.7–1286 / 86
HSPF2 · BTU/Wh7.8–8.586 / 86
Cooling capacity · BTU/h52,500–54,50086 / 86
Heating capacity at 47°F / 8.3°C · BTU/h50,000–53,50086 / 86
Heating capacity at 17°F / −8.3°C · BTU/h48,000–51,00086 / 86
Heating capacity at 5°F / −15°C · BTU/h37,000–40,00086 / 86
COP at 5°F / −15°C1.6–1.8486 / 86
Equipment / loop typeHP - Split System86 / 86
Refrigerant / source-reported GWPR-410A (GWP:2088)86 / 86
Compressor stagingContinuously variable86 / 86
Connected capabilityNo86 / 86

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4TXCD010DS3+ furnace: S8V2C100M5PCBAHRI reference: 21425352418.008.00390001.70EPA 3549730 →
4TXCD010DS3+ furnace: S8V2C100M5PDBAHRI reference: 21425352218.008.00390001.70EPA 3549731 →
4PX*DU60BS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 21425351618.008.20395001.80EPA 3549737 →
4PX*DU60BS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 21425351418.008.20395001.80EPA 3549738 →
4TXCD010DS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 21425352818.008.20395001.80EPA 3549739 →
4TXCD010DS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 21425352618.008.20395001.80EPA 3549740 →
TEM6A0C48H41+TDR+RPAHRI reference: 21542906318.008.50385001.79EPA 3625079 →
TEM6B0C60H51+TDR+RPAHRI reference: 21542906418.008.50380001.80EPA 3625080 →
4PX*CU60BS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 21582592218.008.20395001.72EPA 3799487 →
4PX*CU60BS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582592418.008.20395001.72EPA 3799489 →
4PX*DU60BS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 21582593018.008.20395001.73EPA 3799490 →
4PX*DU60BS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582593218.008.20395001.73EPA 3799493 →
4TXCC009DS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 21582593418.008.20395001.72EPA 3799495 →
4TXCC009DS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582593618.008.20395001.72EPA 3799497 →
4TXCD010DS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582645018.008.20395001.73EPA 3799618 →
4TXCD010DS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 21582645218.008.20395001.73EPA 3799620 →
4PX*CU60BS3+ furnace: L8V1C100U5VSB+RPAHRI reference: 21263004418.008.20395001.60EPA 4470839 →
4PX*CU60BS3+P0V0C000M50SD+RPAHRI reference: 21263004618.008.20390001.70EPA 4470841 →
4PX*DD60BS3+P0V0D000M50SD+RPAHRI reference: 21263004818.008.20395001.70EPA 4470843 →
4PX*DU60BS3+P0V0C000M50SD+RPAHRI reference: 21263005018.008.10378001.70EPA 4470844 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →