American Standard / AIR-SOURCE HEAT PUMP

4A6V8X36A1

PLATINUM 18 · Platinum 18 · XV18I · source records, page 7

130 published source records · source checked Sep 21, 2026

SEER2 range17.5–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity32,800–35,600BTU/h

Each efficiency range summarizes published EPA records for 4A6V8X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 130 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.5–18130 / 130
EER2 · BTU/Wh11.2–12.2130 / 130
HSPF2 · BTU/Wh7.8–8.5130 / 130
Cooling capacity · BTU/h32,800–35,600130 / 130
Heating capacity at 47°F / 8.3°C · BTU/h28,800–32,800130 / 130
Heating capacity at 17°F / −8.3°C · BTU/h24,800–26,800130 / 130
Heating capacity at 5°F / −15°C · BTU/h19,600–21,000130 / 130
COP at 5°F / −15°C1.67–1.91130 / 130
Equipment / loop typeHP - Split System130 / 130
Refrigerant / source-reported GWPR-410A (GWP:2088)130 / 130
Compressor stagingContinuously variable130 / 130
Connected capabilityNo130 / 130

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*CU36BS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582587218.008.20202001.82EPA 3799635 →
4PX*CU42BS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582587418.008.50204001.84EPA 3799637 →
4PX*CU48BS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582587618.008.50204001.87EPA 3799639 →
4TXCB006DS3+ furnace: S9V2B080U4VSB+LRPAHRI reference: 21680000818.008.20199001.80EPA 4470875 →
4TXCB006DS3+ furnace: S9V2B080U4VSB+RPAHRI reference: 21680000618.008.20199001.80EPA 4470876 →
4PX*BU48BS3+ furnace: S9V2B080D4PSC+RPAHRI reference: 21463998218.008.50202001.80EPA 4470877 →
4PX*BU48BS3+ furnace: S9V2B060D3PSC+RPAHRI reference: 21463998418.008.50202001.80EPA 4470878 →
4PX*BU48BS3+ furnace: S9V2B040D3PSC+RPAHRI reference: 21463998618.008.50206001.80EPA 4470879 →
4PX*BU36BS3+P0V0B000M40SC+RPAHRI reference: 20780568517.508.10196001.78EPA 2527093 →
4TXCB004DS3+P0V0B000M40SC+RPAHRI reference: 20780568917.508.10196001.78EPA 2527097 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →