4A6V7X60A1
PLATINUM 17 · source records, page 3
58 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4A6V7X60A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 58 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–17.1 | 58 / 58 |
| EER2 · BTU/Wh | 11.7–12 | 58 / 58 |
| HSPF2 · BTU/Wh | 8–8.5 | 58 / 58 |
| Cooling capacity · BTU/h | 52,500–54,000 | 58 / 58 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 51,500–53,500 | 58 / 58 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 48,000–51,000 | 58 / 58 |
| Heating capacity at 5°F / −15°C · BTU/h | 38,000–40,000 | 58 / 58 |
| COP at 5°F / −15°C | 1.6–1.8 | 58 / 58 |
| Equipment / loop type | HP - Split System | 58 / 58 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 58 / 58 |
| Compressor staging | Continuously variable | 58 / 58 |
| Connected capability | No | 58 / 58 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4TXCD010DS3+ furnace: S9V2D120U5PSB+LRPAHRI reference: 213826806 | 17.10 | 8.20 | 38500 | 1.70 | EPA 2860925 → |
TEM8A0C48V41+TDR+LRPAHRI reference: 214671752 | 17.10 | 8.50 | 38000 | 1.80 | EPA 3491911 → |
TEM8B0C60V51+TDR+LRPAHRI reference: 214671759 | 17.10 | 8.50 | 38000 | 1.80 | EPA 3491913 → |
4PX*DU60BS3+ furnace: S8V2D120M5PCBAHRI reference: 214639902 | 17.00 | 8.20 | 39000 | 1.70 | EPA 3477161 → |
4PX*DU60BS3+ furnace: S8V2D120M5PDBAHRI reference: 214639904 | 17.00 | 8.20 | 39000 | 1.70 | EPA 3477162 → |
4TXCD010DS3+ furnace: S8V2D120M5PCBAHRI reference: 214639918 | 17.00 | 8.20 | 39000 | 1.70 | EPA 3477165 → |
4TXCD010DS3+ furnace: S8V2D120M5PDBAHRI reference: 214639920 | 17.00 | 8.20 | 39000 | 1.70 | EPA 3477167 → |
4TXCD010DS3+ furnace: S8V2C100M5PDBAHRI reference: 214639916 | 17.00 | 8.10 | 38000 | 1.60 | EPA 3477529 → |
4PX*DU60BS3+ furnace: S8V2C100M5PCBAHRI reference: 214639900 | 17.00 | 8.10 | 38000 | 1.60 | EPA 3477541 → |
4TXCD010DS3+ furnace: S8V2C100M5PCBAHRI reference: 214639914 | 17.00 | 8.10 | 38000 | 1.60 | EPA 3477542 → |
4PX*CU60BS3+ furnace: S9V2C080U5VSB+LRPAHRI reference: 215825834 | 17.00 | 8.10 | 39500 | 1.72 | EPA 3799570 → |
4PX*CU60BS3+ furnace: S9V2C100U5VSB+LRPAHRI reference: 215825836 | 17.00 | 8.10 | 39500 | 1.72 | EPA 3799572 → |
4PX*DU60BS3+ furnace: S9V2C100U5VSB+LRPAHRI reference: 215825842 | 17.00 | 8.10 | 39500 | 1.73 | EPA 3799616 → |
4PX*DU60BS3+ furnace: S9V2C080U5VSB+LRPAHRI reference: 215825844 | 17.00 | 8.10 | 39500 | 1.73 | EPA 3799621 → |
4TXCC009DS3+ furnace: S9V2C080U5VSB+LRPAHRI reference: 215825846 | 17.00 | 8.10 | 39500 | 1.72 | EPA 3799623 → |
4TXCC009DS3+ furnace: S9V2C100U5VSB+LRPAHRI reference: 215825848 | 17.00 | 8.10 | 39500 | 1.72 | EPA 3799625 → |
4TXCD010DS3+ furnace: S9V2C100U5VSB+LRPAHRI reference: 215825850 | 17.00 | 8.10 | 39500 | 1.73 | EPA 3799627 → |
4TXCD010DS3+ furnace: S9V2C080U5VSB+LRPAHRI reference: 215825852 | 17.00 | 8.10 | 39500 | 1.73 | EPA 3799630 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →