American Standard / AIR-SOURCE HEAT PUMP

4A6V7X48A1

PLATINUM 17 · source records, page 6

129 published source records · source checked Sep 21, 2026

SEER2 range17–17.1BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity44,000–47,000BTU/h

Each efficiency range summarizes published EPA records for 4A6V7X48A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 129 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–17.1129 / 129
EER2 · BTU/Wh11.7–12129 / 129
HSPF2 · BTU/Wh8.1–8.5129 / 129
Cooling capacity · BTU/h44,000–47,000129 / 129
Heating capacity at 47°F / 8.3°C · BTU/h40,000–48,000129 / 129
Heating capacity at 17°F / −8.3°C · BTU/h35,200–37,600129 / 129
Heating capacity at 5°F / −15°C · BTU/h27,400–28,800129 / 129
COP at 5°F / −15°C1.7–1.9129 / 129
Equipment / loop typeHP - Split System129 / 129
Refrigerant / source-reported GWPR-410A (GWP:2088)129 / 129
Compressor stagingContinuously variable129 / 129
Connected capabilityNo129 / 129

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*CD60BS3+ furnace: S8V2C080M5PDBAHRI reference: 21463974617.008.20284001.70EPA 3477029 →
4PX*CD60BS3+ furnace: S8V2C080M5PCBAHRI reference: 21463974817.008.20284001.70EPA 3477032 →
4PX*CD60BS3+HORIZ-RT+ furnace: S8V2C100M5PDBAHRI reference: 21463975017.008.20286001.70EPA 3477034 →
4PX*CD60BS3+HORIZ-RT+ furnace: S8V2C100M5PCBAHRI reference: 21463975217.008.20286001.70EPA 3477035 →
4PX*CD60BS3+HORIZ-RT+ furnace: S8V2C080M5PCBAHRI reference: 21463975417.008.20284001.70EPA 3477038 →
4PX*CD60BS3+HORIZ-RT+ furnace: S8V2C080M5PDBAHRI reference: 21463975617.008.20284001.70EPA 3477039 →
4TXCD008DS3+ furnace: S8V2D120M5PCBAHRI reference: 21463985417.008.20288001.80EPA 3477041 →
4TXCD010DS3+ furnace: S8V2C080M5PDBAHRI reference: 21463986217.008.20274001.80EPA 3477049 →
4TXCD010DS3+ furnace: S8V2C100M5PDBAHRI reference: 21463986417.008.20276001.80EPA 3477051 →
4TXCD010DS3+ furnace: S8V2C100M5PCBAHRI reference: 21463986617.008.20276001.80EPA 3477053 →
4TXCD010DS3+ furnace: S8V2D120M5PDBAHRI reference: 21463986817.008.20284001.80EPA 3477055 →
4TXCD010DS3+ furnace: S8V2C080M5PCBAHRI reference: 21463987017.008.20274001.80EPA 3477057 →
4PX*CU60BS3+ furnace: S8V2C080M5PCBAHRI reference: 21463977217.008.20284001.80EPA 3477122 →
4PX*CU60BS3+ furnace: S8V2C080M5PDBAHRI reference: 21463977417.008.20284001.80EPA 3477124 →
4PX*CU60BS3+ furnace: S8V2C100M5PCBAHRI reference: 21463977617.008.20286001.80EPA 3477128 →
4PX*DD60BS3+ furnace: S8V2C080M5PCBAHRI reference: 21463978417.008.20274001.70EPA 3477133 →
4PX*DU48BS3+ furnace: S8V2D120M5PDBAHRI reference: 21463980217.008.20288001.80EPA 3477147 →
4PX*DU48BS3+ furnace: S8V2D120M5PCBAHRI reference: 21463980417.008.20288001.80EPA 3477149 →
4PX*DU60BS3+ furnace: S8V2D120M5PCBAHRI reference: 21463981217.008.20284001.80EPA 3477157 →
4PX*DU60BS3+ furnace: S8V2C100M5PDBAHRI reference: 21463981417.008.20276001.80EPA 3477163 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →