4A6V7X48A1
PLATINUM 17
129 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4A6V7X48A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 129 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–17.1 | 129 / 129 |
| EER2 · BTU/Wh | 11.7–12 | 129 / 129 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 129 / 129 |
| Cooling capacity · BTU/h | 44,000–47,000 | 129 / 129 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 40,000–48,000 | 129 / 129 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 35,200–37,600 | 129 / 129 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,400–28,800 | 129 / 129 |
| COP at 5°F / −15°C | 1.7–1.9 | 129 / 129 |
| Equipment / loop type | HP - Split System | 129 / 129 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 129 / 129 |
| Compressor staging | Continuously variable | 129 / 129 |
| Connected capability | No | 129 / 129 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4PX*DU48BS3+ furnace: S8V2D120M5PCAAHRI reference: 212391520 | 17.10 | 8.20 | 28800 | 1.80 | EPA 2476822 → |
4TXCC009DS3+ furnace: S8V2C100M5PDAAHRI reference: 212391546 | 17.10 | 8.20 | 28600 | 1.80 | EPA 2477071 → |
4TXCC009DS3+ furnace: S8V2C080M5PDAAHRI reference: 212391547 | 17.10 | 8.20 | 28400 | 1.80 | EPA 2477110 → |
TAMXB0C60V51AHRI reference: 212391555 | 17.10 | 8.50 | 27800 | 1.80 | EPA 2477574 → |
4PX*CU60BS3+ furnace: S8V2C080M5PDAAHRI reference: 212391511 | 17.10 | 8.20 | 28400 | 1.80 | EPA 2478336 → |
4TXCD008DS3+ furnace: S8V2D120M5PCAAHRI reference: 212391550 | 17.10 | 8.20 | 28800 | 1.80 | EPA 2478699 → |
4PX*CU60BS3+ furnace: S8V2C080M5PCAAHRI reference: 212391514 | 17.10 | 8.20 | 28400 | 1.80 | EPA 2479586 → |
TAMXB0C48V41AHRI reference: 212391376 | 17.10 | 8.50 | 28000 | 1.80 | EPA 2483435 → |
4PX*CD60BS3+ furnace: S8V2C100M5PCAAHRI reference: 212391492 | 17.10 | 8.20 | 28600 | 1.70 | EPA 2483727 → |
4PX*CD60BS3+ furnace: S8V2C080M5PCAAHRI reference: 212391491 | 17.10 | 8.20 | 28400 | 1.70 | EPA 2483728 → |
4PX*CD60BS3+ furnace: S8V2C080M5PDAAHRI reference: 212391493 | 17.10 | 8.20 | 28400 | 1.70 | EPA 2483729 → |
4PX*CD60BS3+ furnace: S8V2C100M5PDAAHRI reference: 212391494 | 17.10 | 8.20 | 28600 | 1.70 | EPA 2483988 → |
4PX*CU60BS3+ furnace: S8V2C100M5PCAAHRI reference: 212391512 | 17.10 | 8.20 | 28600 | 1.80 | EPA 2483989 → |
4PX*CU60BS3+ furnace: S8V2C100M5PDAAHRI reference: 212391513 | 17.10 | 8.20 | 28600 | 1.80 | EPA 2483990 → |
4PX*DU48BS3+ furnace: S8V2D120M5PDAAHRI reference: 212391519 | 17.10 | 8.20 | 28800 | 1.80 | EPA 2483991 → |
4PX*DU60BS3+ furnace: S8V2D120M5PCAAHRI reference: 212391521 | 17.10 | 8.20 | 28400 | 1.80 | EPA 2483992 → |
4PX*DU60BS3+ furnace: S8V2D120M5PDAAHRI reference: 212391522 | 17.10 | 8.20 | 28400 | 1.80 | EPA 2483993 → |
4TXCC009DS3+ furnace: S8V2C080M5PCAAHRI reference: 212391548 | 17.10 | 8.20 | 28400 | 1.80 | EPA 2483994 → |
TAMXB0C42V41AHRI reference: 212391554 | 17.10 | 8.50 | 27800 | 1.70 | EPA 2483995 → |
4TXCC009DS3+ furnace: S8V2C100M5PCAAHRI reference: 212391549 | 17.10 | 8.20 | 28600 | 1.80 | EPA 2483996 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.