American Standard / AIR-SOURCE HEAT PUMP

4A6V7X36A1

PLATINUM 17 · Platinum 17 · source records, page 7

144 published source records · source checked Sep 21, 2026

SEER2 range17–17.1BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,600–35,600BTU/h

Each efficiency range summarizes published EPA records for 4A6V7X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–17.1144 / 144
EER2 · BTU/Wh11.7–12144 / 144
HSPF2 · BTU/Wh7.8–8.5144 / 144
Cooling capacity · BTU/h33,600–35,600144 / 144
Heating capacity at 47°F / 8.3°C · BTU/h29,000–36,000144 / 144
Heating capacity at 17°F / −8.3°C · BTU/h25,200–26,800144 / 144
Heating capacity at 5°F / −15°C · BTU/h19,800–21,000144 / 144
COP at 5°F / −15°C1.6–1.9144 / 144
Equipment / loop typeHP - Split System144 / 144
Refrigerant / source-reported GWPR-410A (GWP:2088)144 / 144
Compressor stagingContinuously variable144 / 144
Connected capabilityNo144 / 144

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*CD36BS3+HORIZ-RT+ furnace: S8V2C080M5PDBAHRI reference: 21463966817.007.80206001.60EPA 3477511
4PX*CD36BS3+HORIZ-RT+ furnace: S8V2C100M5PCBAHRI reference: 21463966617.008.00206001.60EPA 3477512
4PX*CD36BS3+ furnace: S8V2C080M5PCBAHRI reference: 21463965617.007.80206001.60EPA 3477513
4PX*CD36BS3+ furnace: S8V2C080M5PDBAHRI reference: 21463965817.007.80206001.60EPA 3477514
4PX*CD36BS3+ furnace: S8V2C100M5PCBAHRI reference: 21463966017.008.00206001.60EPA 3477515
4PX*CD36BS3+ furnace: S8V2C100M5PDBAHRI reference: 21463966217.008.00206001.60EPA 3477516
4PX*BD42BS3+HORIZ-RT+ furnace: S8V2B060M4PDBAHRI reference: 21463962617.008.10206001.70EPA 3477517
4PX*BD42BS3+HORIZ-RT+ furnace: S8V2B060M4PCBAHRI reference: 21463962417.008.10206001.70EPA 3477518
4PX*BD42BS3+HORIZ-RT+ furnace: S8V2B080M4PCBAHRI reference: 21463962817.008.10206001.70EPA 3477519
4PX*BD42BS3+HORIZ-RT+ furnace: S8V2B080M4PDBAHRI reference: 21463963017.008.10206001.70EPA 3477520
4PX*BD42BS3+ furnace: S8V2B060M4PDBAHRI reference: 21463961617.008.10206001.70EPA 3477521
4PX*BD42BS3+ furnace: S8V2B080M4PCBAHRI reference: 21463961417.008.10206001.70EPA 3477522
4PX*BD42BS3+ furnace: S8V2B080M4PDBAHRI reference: 21463961817.008.10206001.70EPA 3477523
4PX*CD42BS3+HORIZ-RT+ furnace: S8V2C080M5PCBAHRI reference: 21463967617.008.00202001.70EPA 3477534
4PX*CD42BS3+HORIZ-RT+ furnace: S8V2C080M5PDBAHRI reference: 21463968217.008.00202001.70EPA 3477535
4PX*CD42BS3+HORIZ-RT+ furnace: S8V2C100M5PCBAHRI reference: 21463968017.008.10202001.70EPA 3477536
4PX*CD42BS3+HORIZ-RT+ furnace: S8V2C100M5PDBAHRI reference: 21463967817.008.10202001.70EPA 3477537
4PX*CD42BS3+ furnace: S8V2C080M5PCBAHRI reference: 21463967217.008.00202001.70EPA 3477538
4PX*CD42BS3+ furnace: S8V2C080M5PDBAHRI reference: 21463967017.008.00202001.70EPA 3477539
4PX*CD42BS3+ furnace: S8V2C100M5PDBAHRI reference: 21463967417.008.10202001.70EPA 3477540