American Standard / AIR-SOURCE HEAT PUMP

4A6V7X36A1

PLATINUM 17 · Platinum 17 · source records, page 3

144 published source records · source checked Sep 21, 2026

SEER2 range17–17.1BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,600–35,600BTU/h

Each efficiency range summarizes published EPA records for 4A6V7X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–17.1144 / 144
EER2 · BTU/Wh11.7–12144 / 144
HSPF2 · BTU/Wh7.8–8.5144 / 144
Cooling capacity · BTU/h33,600–35,600144 / 144
Heating capacity at 47°F / 8.3°C · BTU/h29,000–36,000144 / 144
Heating capacity at 17°F / −8.3°C · BTU/h25,200–26,800144 / 144
Heating capacity at 5°F / −15°C · BTU/h19,800–21,000144 / 144
COP at 5°F / −15°C1.6–1.9144 / 144
Equipment / loop typeHP - Split System144 / 144
Refrigerant / source-reported GWPR-410A (GWP:2088)144 / 144
Compressor stagingContinuously variable144 / 144
Connected capabilityNo144 / 144

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*BD42BS3+ furnace: *DHMB060BCV3+LRPAHRI reference: 21382644617.107.80202001.70EPA 2860473 →
4PX*BD42BS3+ furnace: *DHMB060CCV3+LRPAHRI reference: 21382644817.107.80202001.70EPA 2860477 →
4TXCB004DS3+ furnace: *UHMB080CCV3+LRPAHRI reference: 21382654417.108.20204001.70EPA 2860478 →
4TXCB006DS3+ furnace: S9V2B060U4PSB+LRPAHRI reference: 21382656817.108.50206001.80EPA 2860479 →
4PX*BD42BS3+ furnace: *DHMB080ACV3+LRPAHRI reference: 21382645017.107.80202001.70EPA 2860484 →
4PX*BD42BS3+ furnace: *DHMB080CCV3+LRPAHRI reference: 21382645217.107.80202001.70EPA 2860485 →
4PX*BU36BS3+ furnace: *UHMB060CCV3+LRPAHRI reference: 21382645617.108.20204001.80EPA 2860487 →
4PX*BU36BS3+ furnace: *UHMB080ACV3+LRPAHRI reference: 21382645817.108.20204001.80EPA 2860490 →
4PX*BU36BS3+ furnace: *UHMB060ACV3+LRPAHRI reference: 21382645417.108.20204001.80EPA 2860491 →
4PX*BU36BS3+ furnace: *UHMB080CCV3+LRPAHRI reference: 21382646017.108.20204001.80EPA 2860493 →
4TXCC005DS3+ furnace: S9V2C100U4VSA+LRPAHRI reference: 21382659617.108.20202001.80EPA 2860596 →
4TXCC005DS3+ furnace: S9V2C080U5PSC+LRPAHRI reference: 21382659817.108.20204001.80EPA 2860599 →
4TXCC005DS3+ furnace: S9V2C100U4VSB+LRPAHRI reference: 21382660017.108.20202001.80EPA 2860601 →
4TXCC007DS3+ furnace: S9V2C100U4VSB+LRPAHRI reference: 21382660417.108.50204001.80EPA 2860605 →
4TXCC007DS3+ furnace: S9V2C100U4VSA+LRPAHRI reference: 21382660217.108.50204001.80EPA 2860616 →
4PX*CD42BS3+ furnace: S9V2C100D4VSA+LRPAHRI reference: 21382650817.108.10202001.70EPA 2860698 →
4PX*CU36BS3+ furnace: *UHMC100ACV4+LRPAHRI reference: 21382651217.108.20200001.80EPA 2860699 →
4PX*CU36BS3+ furnace: S9V2C100U4VSB+LRPAHRI reference: 21382651417.108.20202001.80EPA 2860705 →
4PX*CD42BS3+ furnace: S9V2C100D4VSB+LRPAHRI reference: 21382651017.108.10202001.70EPA 2860706 →
4PX*CU36BS3+ furnace: S9V2C080U5PSC+LRPAHRI reference: 21382651817.108.20202001.80EPA 2860708 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →