4A6V7X24A1
PLATINUM 17 · source records, page 4
71 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4A6V7X24A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–17.1 | 71 / 71 |
| EER2 · BTU/Wh | 11.7–12 | 71 / 71 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 71 / 71 |
| Cooling capacity · BTU/h | 22,200–24,000 | 71 / 71 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,200–22,400 | 71 / 71 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,300–17,800 | 71 / 71 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,400–13,200 | 71 / 71 |
| COP at 5°F / −15°C | 1.6–1.9 | 71 / 71 |
| Equipment / loop type | HP - Split System | 71 / 71 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 71 / 71 |
| Compressor staging | Continuously variable | 71 / 71 |
| Connected capability | No | 71 / 71 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4TXCB004DS3+ furnace: S9V2B040U3VSB+LRPAHRI reference: 213826416 | 17.10 | 8.50 | 12700 | 1.80 | EPA 2860656 → |
TEM8A0B24V21+TDR+LRPAHRI reference: 214671711 | 17.10 | 8.50 | 13200 | 1.90 | EPA 3491899 → |
TEM8A0B30V31+TDR+LRPAHRI reference: 214671713 | 17.10 | 8.50 | 13100 | 1.90 | EPA 3491901 → |
4PX*BU30BS3+ furnace: S8V2A040M3PDBAHRI reference: 214639576 | 17.00 | 8.10 | 12700 | 1.60 | EPA 3477341 → |
4PX*BU36BS3+ furnace: S8V2A040M3PCBAHRI reference: 214639578 | 17.00 | 8.20 | 12400 | 1.80 | EPA 3477344 → |
4TXCB003DS3+ furnace: S8V2A040M3PCBAHRI reference: 214639584 | 17.00 | 8.10 | 12700 | 1.60 | EPA 3477348 → |
4TXCB003DS3+ furnace: S8V2A040M3PDBAHRI reference: 214639586 | 17.00 | 8.10 | 12700 | 1.60 | EPA 3477351 → |
4TXCB004DS3+ furnace: S8V2A040M3PCBAHRI reference: 214639588 | 17.00 | 8.20 | 12500 | 1.70 | EPA 3477354 → |
4TXCB004DS3+ furnace: S8V2A040M3PDBAHRI reference: 214639590 | 17.00 | 8.20 | 12500 | 1.70 | EPA 3477355 → |
4TXCB003DS3+ furnace: S9V2B060U4VSB+LRPAHRI reference: 215825766 | 17.00 | 8.10 | 13100 | 1.72 | EPA 3799500 → |
4PX*BU30BS3+ furnace: S9V2B060U4VSB+LRPAHRI reference: 215825760 | 17.00 | 8.10 | 13100 | 1.72 | EPA 3799614 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →