American Standard / AIR-SOURCE HEAT PUMP

4A6V7X24A1

PLATINUM 17 · source records, page 2

71 published source records · source checked Sep 21, 2026

SEER2 range17–17.1BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,000BTU/h

Each efficiency range summarizes published EPA records for 4A6V7X24A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–17.171 / 71
EER2 · BTU/Wh11.7–1271 / 71
HSPF2 · BTU/Wh7.8–8.571 / 71
Cooling capacity · BTU/h22,200–24,00071 / 71
Heating capacity at 47°F / 8.3°C · BTU/h18,200–22,40071 / 71
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,80071 / 71
Heating capacity at 5°F / −15°C · BTU/h12,400–13,20071 / 71
COP at 5°F / −15°C1.6–1.971 / 71
Equipment / loop typeHP - Split System71 / 71
Refrigerant / source-reported GWPR-410A (GWP:2088)71 / 71
Compressor stagingContinuously variable71 / 71
Connected capabilityNo71 / 71

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4TXCB003DS3+ furnace: L8V1A040U3VSB+LRPAHRI reference: 21382636617.107.80128001.60EPA 2860427 →
4TXCB003DS3+ furnace: L8V1A060U3VSB+LRPAHRI reference: 21382636817.108.00128001.60EPA 2860430 →
4TXCB004DS3+ furnace: S9V2B060U3VSA+LRPAHRI reference: 21382641817.108.50129001.80EPA 2860446 →
4TXCB004DS3+ furnace: S9V2B060U4PSB+LRPAHRI reference: 21382642217.108.50129001.80EPA 2860450 →
4TXCB004DS3+ furnace: S9V2B060U4PSC+LRPAHRI reference: 21382642417.108.50129001.80EPA 2860453 →
4TXCB004DS3+ furnace: S9V2B060U3VSB+LRPAHRI reference: 21382642017.108.50129001.80EPA 2860456 →
4PX*BU30BS3+ furnace: S9V2B040U3PSB+LRPAHRI reference: 21382630417.108.20129001.70EPA 2860505 →
4PX*BU30BS3+ furnace: *UHMB060ACV3+LRPAHRI reference: 21382630617.108.20130001.70EPA 2860507 →
4PX*BU30BS3+ furnace: *UHMB080ACV3+LRPAHRI reference: 21382630817.108.20131001.70EPA 2860510 →
4PX*BU30BS3+ furnace: *UHMB080CCV3+LRPAHRI reference: 21382631017.108.20131001.70EPA 2860511 →
4PX*BU30BS3+ furnace: L8V1A040U3VSB+LRPAHRI reference: 21382631217.107.80128001.60EPA 2860513 →
4PX*BU30BS3+ furnace: L8V1A060U3VSB+LRPAHRI reference: 21382631417.108.00128001.60EPA 2860515 →
4PX*BU36BS3+ furnace: L8V1A060U3VSB+LRPAHRI reference: 21382632017.108.20125001.80EPA 2860521 →
4PX*BU36BS3+ furnace: L8V1A040U3VSB+LRPAHRI reference: 21382632217.108.20125001.80EPA 2860523 →
4PX*BU36BS3+ furnace: *UHMB080CCV3+LRPAHRI reference: 21382632417.108.50128001.80EPA 2860526 →
4PX*BU36BS3+ furnace: *UHMB060CCV3+LRPAHRI reference: 21382632617.108.50127001.80EPA 2860527 →
4PX*BU36BS3+ furnace: *UHMB060ACV3+LRPAHRI reference: 21382632817.108.50127001.80EPA 2860530 →
4PX*BU36BS3+ furnace: S9V2B040U3VSB+LRPAHRI reference: 21382633017.108.50126001.80EPA 2860535 →
4PX*BU36BS3+ furnace: S9V2B040U3VSA+LRPAHRI reference: 21382633217.108.50126001.80EPA 2860537 →
4PX*BU36BS3+ furnace: S9V2B040U3PSB+LRPAHRI reference: 21382633417.108.50126001.80EPA 2860544 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →